CHELSEA, MA —
OSHA Inspection: J.S.B. INDUSTRIES
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of J.S.B. INDUSTRIES in 130 CRESCENT AVENUE, CHELSEA, MA 02150 (NAICS 311812). OSHA activity number 347103475.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J.S.B. INDUSTRIES
- Site address
- 130 CRESCENT AVENUE
- City
- CHELSEA
- State
- MA
- ZIP
- 02150
- Mailing
- 130 CRESCENT AVENUE, CHELSEA, MA 02150
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311812
- Employees
- 250
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 I
- Issued
- Mar 29, 2024
- Penalty
- Initial $16,131 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i) - Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Location - Production Area On or about 11/14/23, an employee was injured while cleaning a Fedco Model PD414 Hopper without utilizing Lock-Out/Tag-Out procedures.
Recent events (3)
- — F (S) $0
- — C (S) $16131
- — Z (S) $16131
1910.147 C07 I
- Issued
- Mar 29, 2024
- Abate by
- Oct 28, 2024
- Penalty
- Initial $88,721 · Current $16,131 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i) - The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: Location - Production Area On or about 11/14/23, an employee cleaned a Fedco Model PD414 Hopper without an appropriate level of training. J.S.B. Industries, Inc. DBA Muffin Town was previously cited for a violation of occupational safety and health standard 1910.147(c)(7)(i) which was contained in OSHA inspection number 1611370, Citation 1, Item 3, and was affirmed as final order on 10/31/22, with respect to a workplace located at 130 Crescent Ave, Chelsea, MA 02150.
Recent events (3)
- — F (S) $16131
- — C (R) $88721
- — Z (R) $88721
1910.212 A01
- Issued
- Mar 29, 2024
- Abate by
- Oct 28, 2024
- Penalty
- Initial $88,721 · Current $16,131 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): - One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Location - Production Area On or about 11/14/23, employees are exposed to caught in-or-between hazards while cleaning moving parts within a Fedco Model PD414 Hopper which were not guarded. J.S.B. Industries, Inc. DBA Muffin Town was previously cited for a violation of occupational safety and health standard 1910.212(a)(1) which was contained in OSHA inspection number 1611370, Citation 1, Item 2, and was affirmed as final order on 10/31/22, with respect to a workplace located at 130 Crescent Ave, Chelsea, MA 02150.
Recent events (3)
- — F (R) $16131
- — C (R) $88721
- — Z (R) $88721
1910.147 C04 II A
- Issued
- Mar 29, 2024
- Abate by
- Oct 28, 2024
- Penalty
- Initial $1,423 · Current $804 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(A) - The energy control procedures did not contain a specific statement on the intended use of the procedure: Location - Production Area On or about 11/14/23, the written Lockout Tagout procedure for the Fedco Model PD414 Hopper did not include a statement regarding the intended use of the procedure
Recent events (3)
- — F (O) $803.5
- — C (O) $1423
- — Z (O) $1423
1910.147 C06 II
- Issued
- Mar 29, 2024
- Abate by
- Oct 28, 2024
- Penalty
- Initial $1,423 · Current $804 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(ii) - The employer did not certify that periodic inspections of the energy control procedures had been performed: Location - Production Floor On or about 11/14/2023, periodic inspections of the energy control procedures developed for the Fedco Model PD414 Hopper had not been certified.
Recent events (3)
- — F (O) $803.5
- — C (O) $1423
- — Z (O) $1423
More inspections in this industry (NAICS 311812)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347103475.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.