On , OSHA opened a referral safety inspection of ALLEGIANT HEALTH in 75 NORTH INDUSTRY COURT, DEER PARK, NY 11729 (NAICS 325412). OSHA activity number 347104481.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Allegiant Health — free Get an email when a new federal OSHA severe-injury report for Allegiant Health is published. One employer, no account, unsubscribe in one click.
Establishment
ALLEGIANT HEALTH
Site address
75 NORTH INDUSTRY COURT
City
DEER PARK
State
NY
ZIP
11729
Mailing
75 NORTH INDUSTRY COURT, DEER PARK, NY 11729
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325412
Employees
80
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II B

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
May 7, 2024
Abate by
May 24, 2024
Penalty
Initial $11,292 · Current $6,200 Reduced
29 CFR  1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.   a) Workplace, Production Area, Line 11 - Employees performing adjustments were exposed to hazardous energy as a result of the employer's  written energy control procedures did not include machine specific procedures that contain clear and specific steps for the shut down, isolation and securing of machines such as, but not limited to an Uhlmann Blister Machine Model UPS-2MT; on or about 11/10/23.    Note:  In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (3)
  • — R (O) $6200
  • — C (S) $11292
  • — Z (S) $11292

1910.147 C07 I

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
May 7, 2024
Abate by
May 24, 2024
Penalty
Initial $11,292 · Current $6,200 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:  a) Workplace, Production Area, Line 11 - The employees were performing servicing  on an Uhlmann Blister Machine Model UPS-2MT without having received adequate instruction on the safe application, usage, and removal of the electrical and mechanical energy controls are acquired by employees; on or about 11/10/23.  Note:  In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (3)
  • — R (O) $6200
  • — C (S) $11292
  • — Z (S) $11292