WATERFORD, WI —
OSHA Inspection: GARCIA'S ROOFING, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GARCIA'S ROOFING, LLC. in 28925 KRAMER DR., WATERFORD, WI 53185 (NAICS 238160). OSHA activity number 347108292.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GARCIA'S ROOFING, LLC.
- Site address
- 28925 KRAMER DR.
- City
- WATERFORD
- State
- WI
- ZIP
- 53185
- Mailing
- 2960 S.8TH ST., MILWAUKEE, WI 53215
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.20 B02
- Issued
- Apr 9, 2024
- Abate by
- Apr 26, 2024
- Penalty
- Initial $3,457 · Current $2,420 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s) (a) On or about November 16, 2023, the employer did not ensure the competent person was conducting frequent and regular inspections of the job site, to ensure Personal Protective Equipment such as hard hats were being worn, fall protection was being used, that ladders were installed properly, and job site conditions were maintained safe.
Recent events (3)
- — F (S) $2419.9
- — C (S) $3457
- — Z (S) $3457
1926.100 A
- Issued
- Apr 9, 2024
- Abate by
- Apr 19, 2024
- Penalty
- Initial $3,457 · Current $2,420 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) On or about November 16, 2023, the employer did not ensure that the employee assisting in roofing operations (ground workers) were protected from potential falling objects from above by the use of a protective helmet. This exposed the employee to a struck-by hazard from a height of 12 foot, nine (9) inches or more by building material remnants and tools located above the ground level employees.
Recent events (3)
- — F (S) $2419.9
- — C (S) $3457
- — Z (S) $3457
1926.501 B13
- Issued
- Apr 9, 2024
- Penalty
- Initial $4,839 · Current $3,387 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On or about November 16, 2023, employees conducting roofing work on an 8:12 pitch roof were not protected from falling to the lower level. This exposed employees to a fall hazard of approximately 12 feet, 9 inches on the North side of the roof, and 25 feet on the West and East sides of the roof near the ridge onto grass and concrete.
Recent events (3)
- — F (S) $3387.3
- — C (S) $4839
- — Z (S) $4839
1926.1053 B01
- Issued
- Apr 9, 2024
- Abate by
- Apr 19, 2024
- Penalty
- Initial $3,457 · Current $2,420 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where a portable ladder(s) was used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. (a) On or about November 16, 2023, the Werner Extension ladders erected on the North side of the structure, at the garage, and along the front side of the house while being used for access to the 8:12 pitched roof, did not extend at least three (3) feet above the eave, and/or was not secured to the structure when it was not sufficiently extended. This exposed employees accessing the roof to a fall hazard of approximately twelve 12 feet, 9 inches onto grass and concrete.
Recent events (3)
- — F (S) $2419.9
- — C (S) $3457
- — Z (S) $3457
More inspections in this industry (NAICS 238160)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347108292.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.