Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SCHELL & KAMPETER, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SCHELL & KAMPETER, INC. in 800 SOUTH MAIN STREET, DUMAS, AR 71639 (NAICS 311111). OSHA activity number 347114027.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Schell & Kampeter, INC. — free Get an email when a new federal OSHA severe-injury report for Schell & Kampeter, INC. is published. One employer, no account, unsubscribe in one click.
Site address
800 SOUTH MAIN STREET
City
DUMAS
State
AR
ZIP
71639
Mailing
103 N. OLIVE ST., META, MO 65058
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311111
Employees
215
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
May 9, 2024
Abate by
Jun 5, 2024
Penalty
Initial $16,131 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   On or about November 12, 2023, in Plant #3, employees were performing servicing and maintenance activities such as, but not limited to cleaning the roller clamps on the Thiele Bag Placer, Serial #7138A110, without utilizing the documented energy control procedures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $16131

1910.147 D03

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
May 9, 2024
Abate by
Jun 5, 2024
Penalty
Initial $16,131 · Current $0 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:  On or about November 12, 2023, in Plant #3, employees performed servicing and maintenance activities on equipment such as, but not limited to, the Thiele Bag Placer, Serial #7138A110.  All energy sources including, but not limited to pneumatic energy, were not isolated.
Recent events (2)
  • — I (S) $0
  • — Z (S) $16131

1910.147 D05 I

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
May 9, 2024
Abate by
Jun 5, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices:  On or about November 12, 2023, in Plant #3, employees performed servicing and maintenance activities on equipment such as, but not limited to the Thiele Bag Placer, Serial #7138A110.  Stored energy such as, but not limited to pneumatic energy was not relieved, disconnected, restrained, and otherwise rendered safe.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D06

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
May 9, 2024
Abate by
Jun 5, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished:  On or about November 12, 2023, in Plant #3, employees performed service and maintenance on equipment including but not limited to Thiele Bag Placer, Serial #7138A110, without verifying the isolation and de-energization of the equipment being serviced and/or maintained.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 F03 I

Serious Gravity 10 1 instance 3 exposed
Issued
May 9, 2024
Abate by
Jun 5, 2024
Penalty
Initial $16,131 · Current $16,131
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew, craft, department, or other group:  On or about November 12, 2023, in Plant #3, employees performed servicing and maintenance activities such as, but not limited to cleaning the roller clamps on the Thiele Bag Placer, Serial #7138A110.  Group energy control procedures were not utilized to ensure protection of all employees performing servicing and maintenance.
Recent events (2)
  • — I (S) $16131
  • — Z (S) $16131

View Schell & Kampeter, INC.'s full OSHA safety record →