Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NATIONAL MAINTENANCE & REPAIR, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NATIONAL MAINTENANCE & REPAIR, INC. in 401 W HAWTHORNE AVE, HARTFORD, IL 62048 (NAICS 336611). OSHA activity number 347114514.

Watch National Maintenance & Repair, INC. — free Get an email when a new federal OSHA severe-injury report for National Maintenance & Repair, INC. is published. One employer, no account, unsubscribe in one click.
Site address
401 W HAWTHORNE AVE
City
HARTFORD
State
IL
ZIP
62048
Mailing
P.O. BOX 38, HARTFORD, IL 62048
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
23
Ownership type
A

2 citations on file for this inspection.

1915.89 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $10372.00 · Current $6223.00 Reduced
1915.89(d)(1):  The employer did not establish and implement a written procedure to prevent energization or startup, or the release of hazardous energy, during the servicing of a machine, equipment, or system:  On or about November 15, 2023, the employer did not establish and implement a written procedure to prevent energization of a Delco Products Div of General Motors Generator, Model Number E6625HF, Serial Number 16-R-73 during the servicing of the machine by an employee.
Recent events (2)
  • — I (S) $6223
  • — Z (S) $10372

1915.89 Q01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1915.89(q)(1): The employer did not conduct an audit of the lockout/tags-plus program and procedures currently in use at least annually to ensure that the procedures and the requirements of this section are being followed and to correct any deficiencies:   On and before November 15, 2023, the employer did not conduct an audit of the lockout/tags-plus program and procedures currently in use to ensure that the procedure for work associated with a portable generator was in written form.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0