Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SULLIVAN MANUFACTURING CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SULLIVAN MANUFACTURING CORPORATION in 10201 NORTH ENTERPRISE DRIVE, MEQUON, WI 53092 (NAICS 332322). OSHA activity number 347115339.

Watch Sullivan Manufacturing Corporation — free Get an email when a new federal OSHA severe-injury report for Sullivan Manufacturing Corporation is published. One employer, no account, unsubscribe in one click.
Site address
10201 NORTH ENTERPRISE DRIVE
City
MEQUON
State
WI
ZIP
53092
Mailing
10201 NORTH ENTERPRISE DRIVE, MEQUON, WI 53092
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
332322
Employees
5
Ownership type
A

10 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $6452.00 · Current $3871.00 Reduced
29 CFR  1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  a) On or about November 20, 2023, at the workplace located at 10201 North Enterprise Drive, Mequon, WI 53092, the employer did not develop or document an energy control program consisting of an energy control procedure, employee training and periodic inspections, for employees that were engaged in service and maintenance activities on equipment, such as, but not limited to, Bridgeport VMC 800, Hardinge Conquest 65, Hardinge Conquest T42, where the unexpected energizing, start up or release of stored energy could occur and cause injury.
Recent events (2)
  • — I (S) $3871.2
  • — Z (S) $6452

1910.147 C07 I A

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.   (a) On or about November 20, 2023, at the workplace located at 10201 North Enterprise Drive, Mequon, WI 53092, the employer did not establish a program consisting of employee training to ensure that each authorized employee shall be instructed in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I B

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure.  (a) On or about November 20, 2023, at the workplace located at 10201 North Enterprise Drive, Mequon, WI 53092, the employer did not establish a program consisting of employee training to ensure that each affected employee shall be instructed in the purpose and use of the energy control procedure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 2 instances 2 exposed
Issued
Penalty
Initial $6452.00 · Current $3871.00 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  (a) On or about November 20, 2023, at the workplace located at 10201 North Enterprise Drive, Mequon, WI 53092, in the main production area employees were exposed to struck-by and caught-by hazards when operating a Hardinge Conquest T42 with the interlock for the door guards disabled.  (b) On or about November 20, 2023, at the workplace located at 10201 North Enterprise Drive, Mequon, WI 53092, in the main production area employees were exposed to struck-by and caught-by hazards when operating a Bridgeport VMC 800 with the interlock for the door guards disabled.
Recent events (2)
  • — I (S) $3871.2
  • — Z (S) $6452

1910.219 C04 I

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $5531.00 · Current $0.00 Reduced
1910.219(c)(4)(i)  Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft:(a) (LOCATION) (IDENTIFY SPECIFIC OPERATION(S) AND/OR CONDITIONS) (DESCRIBE HAZARD(S) WHERE NECESSARY)Note:  Does not apply if guarded by nonrotating caps or sleeves. 29 CFR  1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections.  (a) On or about November 20, 2023, at the workplace located at 10201 North Enterprise Drive, Mequon, WI 53092, in the machine shop, an employee operated the grinder to deburr parts, that did not have guards installed which covered the spindle end, nut, flange projections to prevent contact. Therefore, exposing employees to entanglement and struck by hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $5531

1910.215 A04

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work.  a) On or about November 20, 2023, at the workplace located at 10201 North Enterprise Drive, Mequon, WI 53092, employees operated a bench grinder that lacked a work rest on both sides exposing them to a caught-in hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B09

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch:  (a) On or about November 20, 2023, at the workplace located at 10201 North Enterprise Drive, Mequon, WI 53092, in the machine shop, employees used an abrasive wheel bench grinder that was not equipped with a tongue guard, exposing employees to a stuck-by hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $4610.00 · Current $0.00 Reduced
29 CFR  1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met.  (a) On or about November 20, 2023, at the workplace located at 10201 North Enterprise Drive, Mequon, WI 53092, a written hazard communication program was not maintained at the workplace where employees worked with hazardous chemicals including but not limited to Machine Coolant SS-200, ZEP Industrial Purple Degreaser, and Anti-Rust 118-H Rust Inhibiter.
Recent events (2)
  • — I (O) $0
  • — Z (S) $4610

1910.1200 G01

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use.  (a) On or about November 20, 2023, at the workplace located at 10201 North Enterprise Drive, Mequon, WI 53092, the employer did not have a safety data sheet (SDS) for the following chemicals: Machine Coolant SS-200, ZEP Industrial Purple Degreaser, Anti-Rust 118-H Rust Inhibiter, Trueguard Way Lube 68, Trueguard AW-32 Hydraulic Oil, and Protec CDF 3004 Machine Cleaner.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area.  (a) On or about November 20, 2023, at the workplace located at 10201 North Enterprise Drive, Mequon, WI 53092, effective information and training were not provided to the employees that worked with hazardous chemicals, including but not limited to Machine Coolant SS-200, ZEP Industrial Purple Degreaser, and Anti-Rust 118-H Rust Inhibiter exposing them to skin irritation, eye irritation, and inhalation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347115339.