Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PENNSYLVANIA MEDICAL SOLUTIONS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PENNSYLVANIA MEDICAL SOLUTIONS, LLC in 2000 ROSANNA AVENUE, SCRANTON, PA 18509 (NAICS 111419). OSHA activity number 347119638.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pennsylvania Medical Solutions, LLC — free Get an email when a new federal OSHA severe-injury report for Pennsylvania Medical Solutions, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2000 ROSANNA AVENUE
City
SCRANTON
State
PA
ZIP
18509
Mailing
2000 ROSANNA AVENUE, SCRANTON, PA 18509
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
111419
Employees
180
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 57 exposed
Issued
Mar 13, 2024
Abate by
May 2, 2024
Penalty
Initial $9,795 · Current $7,836 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the recognized hazard of working from an elevated platform with a guardrail system that was designed such that is had gaps large enough for a sphere of nineteen (19) inches in diameter could pass through it creating a possibility of employees falling to the walking-working surface below:   (a) Cultivation Department - On or about November 21, 2023, employees working from elevated platforms while cultivating cannabis plants were exposed to a fall hazard of approximately five (5) feet because the chain system used for guardrails at either end of the platforms were designed such that a sphere of nineteen (19) inches in diameter could pass through it.  Abatement Certification Required.
Recent events (2)
  • — I (S) $7836
  • — Z (S) $9795

5(a)(1)

Serious Gravity 5 1 instance 57 exposed
Issued
Mar 13, 2024
Penalty
Initial $9,795 · Current $7,836 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the recognized hazard of electrical outlets that were not equipped with a faceplate creating a possibility of employees receiving electrical shocks when using the outlets:  (a) On or about November 17, 2023, employees working in Grow Room 3 were exposed to shock hazards because numerous electrical outlets were not installed with faceplates.   Abatement Certification Not Required.
Recent events (2)
  • — I (S) $7836
  • — Z (S) $9795

5(a)(1)

Deleted Serious Gravity 5 3 instances 57 exposed
Issued
Mar 13, 2024
Abate by
Apr 15, 2024
Penalty
Initial $9,795 · Current $0 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the recognized hazard of an emergency exit access being less twenty-eight (28) inches in width exposing employees to the potential of smoke inhalation and burns when evacuating the area in an emergency:   (a) Grow Room 3 - On or about November 21, 2023, employees working in Grow Room 3 were exposed to a fire hazard because the width between grow tables leading to the exit was measured to be restricted to widths ranging from nineteen and a half (19.5) inches to twenty-seven (27) inches at points.   (b) Grow Room 4 - On or about November 21, 2023, employees working in Grow Room 4 were exposed to a fire hazard because the width between grow tables leading to the exit was measured to be restricted to widths ranging from fourteen (19.5) inches to twenty-four (24) inches at points.   (c) Grow Room 9 - On or about November 21, 2023, employees working in Grow Room 9 were exposed to a fire hazard because the width between grow tables leading to the exit was measured to be restricted to twenty-four (24) inches in width.   Abatement Certification Required.
Recent events (3)
  • — F (S) $0
  • — C (S) $9795
  • — Z (S) $9795

View Pennsylvania Medical Solutions, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347119638.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.