Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DEKA RESEARCH & DEVELOPMENT CORP

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DEKA RESEARCH & DEVELOPMENT CORP in 400 COMMERCIAL STREET, MANCHESTER, NH 03101 (NAICS 541715). OSHA activity number 347120586.

Watch Deka Research & Development Corp — free Get an email when a new federal OSHA severe-injury report for Deka Research & Development Corp is published. One employer, no account, unsubscribe in one click.
Site address
400 COMMERCIAL STREET
City
MANCHESTER
State
NH
ZIP
03101
Mailing
340 COMMERCIAL STREET, MANCHESTER, NH 03101
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541715
Employees
50
Ownership type
A

3 citations on file for this inspection.

1910.134 C02 II

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6913.00 · Current $6913.00
29 CFR  1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:  a.  1st floor ID shop - On or about November 21, 2024, employees voluntarily wore 1/2 face elastomeric respirators during spray painting and model making activities, and the employer did not establish and implement a written respiratory protection program which included medical evaluation, cleaning, storage, and maintenance elements.
Recent events (1)
  • — Z (S) $6913

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:   a.  1st floor ID shop - On or about November 21, 2024, employees voluntarily wore 1/2 face elastomeric respirators during spray painting and model making activities, and the employer did not provide a medical evaluation.
Recent events (1)
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:    a.  1st floor ID shop - On or about November 21, 2024, employees voluntarily wore 1/2 face elastomeric respirators during spray painting and model making activities, and a respirator was hanging from a valve in the paint mixing room.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347120586.