OSHA Inspection: SILVINO SEUCEDO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SILVINO SEUCEDO in 112 INDUSTRIAL DR., BEAVER DAM, WI 53916 (NAICS 238160). OSHA activity number 347121162.

Watch Silvino Seucedo — free Get an email when a new federal OSHA severe-injury report for Silvino Seucedo is published. One employer, no account, unsubscribe in one click.
Establishment
SILVINO SEUCEDO
Site address
112 INDUSTRIAL DR.
City
BEAVER DAM
State
WI
ZIP
53916
Mailing
1125 WEST MAIN STREET, LITTLE CHUTE, WI 54911
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
9
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 6 exposed
Issued
Penalty
Initial $4839.00 · Current $4839.00
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b).   On or about November 21, 2023 each employee engaged in residential construction activities such as, re-roofing an apartment complex roof with a pitch of 3/12 that was approximately 17' 6" above the next lower level, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.
Recent events (1)
  • — Z (S) $4839

1926.1053 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $3457.00 · Current $3457.00
29 CFR  1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  On or about November 21, 2023 portable ladders were used for access to the roof of an apartment building and the ladder side rails did not extend at least 3 feet above the roof edge.
Recent events (1)
  • — Z (S) $3457

View SILVINO SEUCEDO's full OSHA safety record →