Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MAZE ROOFING & CONSTRUCTION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MAZE ROOFING & CONSTRUCTION in 3201 N. SYLVANIA AVENUE, FORT WORTH, TX 76111 (NAICS 238160). OSHA activity number 347123176.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Maze Roofing & Construction — free Get an email when a new federal OSHA severe-injury report for Maze Roofing & Construction is published. One employer, no account, unsubscribe in one click.
Site address
3201 N. SYLVANIA AVENUE
City
FORT WORTH
State
TX
ZIP
76111
Mailing
4417 BELMONT AVENUE, DALLAS, TX 75204
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

6 citations on file for this inspection.

1926.21 B02

Serious Gravity 1 1 instance 6 exposed
Issued
Feb 26, 2024
Abate by
Mar 25, 2024
Penalty
Initial $2,074 · Current $1,244 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury.  On or about November 14, 2023, and at times prior thereto, workers performing roofing activities were not provided hazard recognition and avoidance training when exposed to hazards such as but not limited to energized power lines and electrical shock hazards.
Recent events (2)
  • — I (S) $1244.4
  • — Z (S) $2074

1926.416 A01

Serious Gravity 10 1 instance 6 exposed
Issued
Feb 26, 2024
Abate by
Mar 25, 2024
Penalty
Initial $4,839 · Current $2,903 Reduced
29 CFR 1926.416(a)(1): The employer permitted employees to work in close proximity to energized, unguarded, and ungrounded electric power circuits that the employee could contact in the course of their work:  On or about November 14, 2023, and at times prior thereto, employees working on building roofs were exposed to electric shock hazards when they were not protected from energized power lines.
Recent events (2)
  • — I (S) $2903.4
  • — Z (S) $4839

1926.416 A03

Serious Gravity 10 1 instance 6 exposed
Issued
Feb 26, 2024
Abate by
Mar 25, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.416(a)(3): The employer began work without determining if employees could contact any part of an energized circuit and did not post warning signs and advise employees of the location of the circuit, hazards, and protective measures they need to take.    On or about November 14, 2023, and at time prior thereto, the employer did not post warnings signs or advise employees of the location of the energized electrical lines on the job site exposing them to electrical shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Feb 26, 2024
Abate by
Mar 25, 2024
Penalty
Initial $3,457 · Current $2,074 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  On or about November 14, 2023, and at times prior thereto, the employer did not ensure that workers/employees engaged in sealing roofs with silicone sealant were tied off or protected from fall hazards greater than 6 feet.
Recent events (2)
  • — I (S) $2074.2
  • — Z (S) $3457

1926.503 A01

Other-than-serious 1 instance 6 exposed
Issued
Feb 26, 2024
Abate by
Mar 25, 2024
Penalty
Initial $388 · Current $233 Reduced
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:    On or about November 14, 2023, and at times prior thereto, a training program and formal training on how to recognize and avoid fall hazards was not provided where employees engaged in applying roofing materials were not provided fall protection over 6 feet.
Recent events (2)
  • — I (O) $232.8
  • — Z (O) $388

1926.503 B01

Other-than-serious 1 instance 6 exposed
Issued
Feb 26, 2024
Abate by
Mar 18, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.  On or about November 14, 2023, and at times prior thereto, written training certifications were not prepared or provided to OSHA upon requests for employees who are required to use fall protection.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347123176.