OSHA Inspection: RHS STEEL CONSTRUCTORS, LLC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of RHS STEEL CONSTRUCTORS, LLC. in 1201 S. PARK ST., PECOS, TX 79772 (NAICS 236220). OSHA activity number 347124745.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RHS Steel Constructors, LLC. — free Get an email when a new federal OSHA severe-injury report for RHS Steel Constructors, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
1201 S. PARK ST.
City
PECOS
State
TX
ZIP
79772
Mailing
1749 NORTH DANVILLE DRIVE P.O. BOX 5255, ABILENE, TX 79608
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
17
Ownership type
A

3 citations on file for this inspection.

1926.351 B02

Serious Gravity 5 2 instances 2 exposed
Issued
Jan 10, 2024
Abate by
Feb 6, 2024
Penalty
Initial $4,465 · Current $2,250 Reduced
29 CFR 1926.351(b)(2): Welding cable(s) in use were not free from improper repair or splices for a minimum distance of 10 feet from the cable end to which the electrode holder was connected:  On or about November 27, 2023, the employer did not ensure that welding generator cables were in good condition. The cables had numerous splices where the cable insulation was replaced with electrical tape. This condition exposed employees to electrical hazards.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $4465

1926.405 G02 IV

Serious Gravity 5 2 instances 2 exposed
Issued
Jan 10, 2024
Abate by
Feb 6, 2024
Penalty
Initial $4,465 · Current $2,250 Reduced
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  Construction Site: On or about November 27, 2023, employees were exposed to electric shock hazards in the following instances:  a) A Bobcat 250 Welder Generator #1 (Serial # NA020169R); the connect torch cable to electrode terminal and work weld output terminal had broken strain reliefs and outer jacket damage.   b) A Bobcat 250 Welder Generator #2 (Serial #MF350255R); the connect torch cable to electrode terminal had a broken strain relief and outer jacket damage.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $4465

1926.150 C01 VIII

Other-than-serious 1 instance 2 exposed
Issued
Jan 10, 2024
Abate by
Feb 6, 2024
Penalty
Initial $501 · Current $500 Reduced
29 CFR  1926.150(c)(1)(viii): Portable fire extinguishers were not inspected periodically in accordance with maintenance and use of portable fire extinguishers, N.F.P.A. No. 10A-1970:  Construction Site: On or about November 27, 2023, a portable fire extinguisher located next to Bobcat 250 Welder Generator #1 (Serial # NA020169R) was not periodically inspected and maintained in an operating condition.
Recent events (2)
  • — I (O) $500
  • — Z (O) $501

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347124745.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.