Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: LEAK REPAIR SPECIALIST LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LEAK REPAIR SPECIALIST LLC in 2029 BROOKSIDE CIRCLE WESTLAND SUBDIVISION LOTS 19 & 20, BOGART, GA 30622 (NAICS 238160). OSHA activity number 347128688.

Watch Leak Repair Specialist LLC — free Get an email when a new federal OSHA severe-injury report for Leak Repair Specialist LLC is published. One employer, no account, unsubscribe in one click.
Site address
2029 BROOKSIDE CIRCLE WESTLAND SUBDIVISION LOTS 19 & 20
City
BOGART
State
GA
ZIP
30622
Mailing
444 CHARESA LANE, DACULA, GA 30019
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 8 exposed
Issued
Penalty
Initial $2679.00 · Current $2679.00
29 CFR  1926.102(a)(1): Employees did not use eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:   a) Roof, Lots 19 & 20, Westland Subdivision, Bogart, GA 30622: On or about 11/28/2023, the employer exposed employees to struck-by hazards while performing roofing installation activities, in that protective eyewear was not provided while operating pneumatic nail guns at 150 PSI.
Recent events (1)
  • — Z (S) $2679

1926.501 B13

Serious Gravity 5 2 instances 8 exposed
Issued
Penalty
Initial $3349.00 · Current $3349.00
29 CFR  1926.501(b)(13):Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:   a) Roof: Lots 19 & 20, Westland Subdivision, Bogart, GA 30662: On or about 11/28/2023, the employer exposed employees to fall hazards of 19-feet, 10-inches from the eave of the 10/12 pitch, in that an adequate fall protection system was not used while using the roof as a walking/working surface.   b)  Roof: Lot 19, Westland Subdivision, Bogart, GA 30662: On or about 11/28/2023, the employer exposed employees to fall hazards of 19-feet, 10-inches from the eave of the 10/12 pitch roof while performing roofing installation activities while connecting a personal fall protection system to a rope tied around the truss as an anchor.
Recent events (1)
  • — Z (S) $3349

1926.552 A04

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.552(a)(4): 29 CFR 1926.552(a)(4): Hoisting ropes were not installed in accordance with the wire rope manufacturers' recommendations.   a) Roof, Lot 19, Westland Subdivision, Bogart, GA 30622: On or about 11/28/2023, the employer exposed employees to struck-by hazards while performing hoisting operations of materials such as but not limited to shingle bundles and ridge caps with the TranzSporter, TP250, material equipment. The system was changed to include the installation of a climbing rope and not the manufacturer's required wire rope.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347128688.