OSHA Inspection: AIR WAVES, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of AIR WAVES, INC. in 7750 GREEN MEADOWS DR N, SUITE A, LEWIS CENTER, OH 43035 (NAICS 313310). OSHA activity number 347139644.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AIR Waves, INC. — free Get an email when a new federal OSHA severe-injury report for AIR Waves, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
AIR WAVES, INC.
Site address
7750 GREEN MEADOWS DR N, SUITE A
City
LEWIS CENTER
State
OH
ZIP
43035
Mailing
7750 GREEN MEADOWS DR N, SUITE A, LEWIS CENTER, OH 43035
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
313310
Employees
95
Ownership type
A

4 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 1 instance 87 exposed
Issued
Mar 18, 2024
Abate by
Apr 5, 2024
Penalty
Initial $8,067 · Current $4,840 Reduced
29 CFR  1910.37(a)(3):Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route.  a.  Located at the downstairs emergency exit between the ink department and packaging areas:  On or about December 4, 2023, the emergency exit was blocked with a merchandise cart.
Recent events (2)
  • — I (S) $4840.2
  • — Z (S) $8067

1910.147 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 18, 2024
Abate by
Apr 5, 2024
Penalty
Initial $11,292 · Current $6,775 Reduced
29 CFR  1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  a. On or about December 4, 2023, and at times prior, employees were required to perform service and maintenance related activities on equipment such as, but not limited to, the Sakurai SC102A2 printing machine. The employer did not develop an emergency control (Lockout/Tagout) program consisting of machine specific procedures, employee training, and periodic inspections, thereby exposing employees machine hazards associated with moving parts.
Recent events (2)
  • — I (S) $6775.4
  • — Z (S) $11292

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 18, 2024
Abate by
Apr 5, 2024
Penalty
Initial $8,067 · Current $4,840 Reduced
29 CFR  1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  a. Located at the squeegee sharpening machine: On or about December 4, 2023, employees were operating the machine with the hinged guard in the raised position exposing employees to the rotating scraper and flying plastic chips. hine.
Recent events (2)
  • — I (S) $4840.4
  • — Z (S) $8067

1910.303 G01

Other-than-serious 2 instances 87 exposed
Issued
Mar 18, 2024
Abate by
Apr 5, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.  a.  Located at electrical panel 8:  On or about December 4, 2023, access to the electrical panel was blocked by a broken pallet which was stored within the 36" required clearance zone in front of the panel.  b.  Located at recessed electrical panel area:  On or about December 4, 2023, access to the electrical panels was blocked by boxes, merchandise, and debris that were stored within the 36" required clearance zone in front of the panel.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View AIR Waves, INC.'s full OSHA safety record →