TUSCUMBIA, AL —
OSHA Inspection: MCVANTAGE PACKAGING, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MCVANTAGE PACKAGING, LLC in 514 HIGHWAY 43 SOUTH, TUSCUMBIA, AL 35674 (NAICS 321920). OSHA activity number 347150443.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MCVANTAGE PACKAGING, LLC
- Site address
- 514 HIGHWAY 43 SOUTH
- City
- TUSCUMBIA
- State
- AL
- ZIP
- 35674
- Mailing
- 514 HIGHWAY 43 SOUTH, TUSCUMBIA, AL 35674
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 109
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Mar 5, 2024
- Abate by
- Mar 29, 2024
- Penalty
- Initial $7,052 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about 11/10/2023 - Pendu Building Area, Pendu Gang Saw (Model: M14205, Serial Number: 14205-9) conveyor system, alternative procedures were not developed and documented for employees removing logs jammed inside the rollers of the machine exposing employees to caught-in hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $7052
1910.219 F03
- Issued
- Mar 5, 2024
- Abate by
- Apr 25, 2024
- Penalty
- Initial $10,578 · Current $8,815 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven 7 feet or less above floors or platforms were not enclosed: (a) On or about 11/10/2023 - Pendu Building Area, the sprockets and chain for the Pendu Gang Saw (Model: M14205, Serial Number: 14205-9) drive were not guarded exposing employees to caught-in hazards.
Recent events (2)
- — I (S) $8815
- — Z (S) $10578
1910.147 C06 II
- Issued
- Mar 5, 2024
- Abate by
- Apr 25, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: (a) On or about 12/07/2023 - Pendu Building Area, no written certification was maintained for periodic inspections of the energy control procedures performed for the Pendu Gang Saw conveyor system, Model: M14205, Serial Number: 14205-9.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Mcvantage Packaging, LLC
View Mcvantage Packaging, LLC's full OSHA safety record →
More inspections in this industry (NAICS 321920)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347150443.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.