ALEXANDER, ND —
OSHA Inspection: AXIP ENERGY SERVICES, LP
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of AXIP ENERGY SERVICES, LP in 3992 146TH AVE NW, ALEXANDER, ND 58831 (NAICS 221210). OSHA activity number 347160939.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AXIP ENERGY SERVICES, LP
- Site address
- 3992 146TH AVE NW
- City
- ALEXANDER
- State
- ND
- ZIP
- 58831
- Mailing
- 1221 MCKINNEY STREET SUITE 3175, HOUSTON, TX 77010
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221210
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 II
- Issued
- Mar 15, 2024
- Abate by
- Apr 19, 2024
- Penalty
- Initial $14,518 · Current $14,518
General-duty citation text
29 CFR 1910.147(c)(4)(ii):The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: (a)On December 12, 2023, At The Rivers Edge Compressor station, 3992 146th Ave NW, Alexander, ND 58831, the employer did not ensure all energy sources were identified and the steps to isolate and verify the procedures were sufficient exposing employees to a flash fire hazard while doing maintenance.
Recent events (2)
- — I (O) $14518
- — Z (S) $14518
1910.147 D05 I
- Issued
- Mar 15, 2024
- Abate by
- Apr 19, 2024
- Penalty
- Initial $14,518 · Current $14,518
General-duty citation text
29 CFR 1910.147(d)(5)(i):All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: (a) On December 12, 2023, At The Rivers Edge Compressor station, 3992 146th Ave NW, Alexander, ND 58831, employees did not relieve all hazardous stored or residual energy exposing employees to flash fire hazards while doing maintenance.
Recent events (2)
- — I (S) $14518
- — Z (S) $14518
1910.147 D06
- Issued
- Mar 15, 2024
- Abate by
- Apr 19, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(6):Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and de-energization of the machine or equipment had been accomplished: (a)On December 12, 2023, At The Rivers Edge Compressor station, 3992 146th Ave NW, Alexander, ND 58831, the authorized employees did not verify that the isolation and de-energization of equipment exposing employees to a hazardous energy release of flammable gas and fire or explosion while doing maintenance.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 F03 II D
- Issued
- Mar 15, 2024
- Abate by
- Apr 19, 2024
- Penalty
- Initial $10,372 · Current $10,372
General-duty citation text
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment: (a) On December 12, 2023, At The Rivers Edge Compressor station, 3992 146th Ave NW, Alexander, ND 58831, all authorized employees did not apply locks to the group lockout box which exposed them to the re-energization and release of hazardous flammable gas, fire and explosion hazards while doing maintenance.
Recent events (2)
- — I (O) $10372
- — Z (S) $10372
More inspections at Axip Energy Services, LP
View Axip Energy Services, LP's full OSHA safety record →
More inspections in this industry (NAICS 221210)
More inspections in ND
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347160939.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.