OSHA Inspection: MAMOU RICE DRIER & WAREHOUSE, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of MAMOU RICE DRIER & WAREHOUSE, INC. in 601 EAST BACCIOCHI AVE, EUNICE, LA 70535 (NAICS 311212). OSHA activity number 347162836.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mamou Rice Drier & Warehouse, INC. — free Get an email when a new federal OSHA severe-injury report for Mamou Rice Drier & Warehouse, INC. is published. One employer, no account, unsubscribe in one click.
Site address
601 EAST BACCIOCHI AVE
City
EUNICE
State
LA
ZIP
70535
Mailing
1738 OLD HWY 13, MAMOU, LA 70554
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311212
Employees
3
Ownership type
A

2 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 4, 2024
Abate by
Apr 30, 2024
Penalty
Initial $5,531 · Current $5,531
29 CFR  1910.22(a)(1):The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition.  a) On or about December 13, 2023, in the west side of the conveyor sysetm, the employer failed to ensure that the work areas were kept clean of Class II combustable dust accumulated on walls and equipment.
Recent events (1)
  • — Z (S) $5531

1910.307 C03

Other-than-serious 1 instance 2 exposed
Issued
Apr 4, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.307(c)(3): The equipment used in the hazardous(classified) location was not of the type and design that would provide protection from the hazards arising from the combustibility and flammability of vapors, liquids, gases, dusts, or other fibers involved.       a) On or about December 13, 2023, Overhead lighting in the conveyor section of the facility was not rated for Class II Combustible Dust and was not approved for the ignitable or combustible properties of the specific dust or fiber that was or could be present exposing employees to explosion hazards.
Recent events (1)