GRANITE CITY, IL —
OSHA Inspection: MAYCO MANUFACTURING, LLC DBA MAYCO INDUSTRIES, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of MAYCO MANUFACTURING, LLC DBA MAYCO INDUSTRIES, INC. in 1200 16TH STREET, GRANITE CITY, IL 62040 (NAICS 331410). OSHA activity number 347166084.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAYCO MANUFACTURING, LLC DBA MAYCO INDUSTRIES, INC.
- Site address
- 1200 16TH STREET
- City
- GRANITE CITY
- State
- IL
- ZIP
- 62040
- Mailing
- 1200 16TH STREET, GRANITE CITY, IL 62040
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331410
- Employees
- 65
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.1025 H01
- Issued
- Jun 7, 2024
- Abate by
- Jul 5, 2024
- Penalty
- Initial $11,409 · Current $7,986 Reduced
General-duty citation text
29 CFR 1910.1025(h)(1): Surfaces. All surfaces shall be maintained as free as practicable of accumulations of lead. On or about May 10, 2024, the employer did not maintain all surfaces in the lunchroom and clean side of the men's locker room as free as practicable of accumulation of lead.
Recent events (2)
- — I (S) $7986.3
- — Z (S) $11409
1910.1025 I04 II
- Issued
- Jun 7, 2024
- Abate by
- Jul 5, 2024
- Penalty
- Initial $11,409 · Current $7,986 Reduced
General-duty citation text
29 CFR 1910.1025(i)(4)(ii): Lunchroom facilities for employees exposed to lead in excess of the permissible exposure limit (PEL), without regard to the use of respirators, were not provided with a temperature controlled, positive pressure, filtered air supply: On or about December 12, 2023, the employer did not ensure the employee lunchroom facility used by all employees exposed to lead in excess of the permissible exposure limit (PEL) was provided with positive pressure.
Recent events (2)
- — I (S) $7986.3
- — Z (S) $11409
More inspections at Mayco Manufacturing, LLC DBA Mayco Industries, INC.
View Mayco Manufacturing, LLC DBA Mayco Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331410)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347166084.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.