SOUTHWICK, MA —
OSHA Inspection: INVALEON TECHNOLOGIES CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of INVALEON TECHNOLOGIES CORPORATION in 201 COLLEGE HWY, SOUTHWICK, MA 01077 (NAICS 238210). OSHA activity number 347169633.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INVALEON TECHNOLOGIES CORPORATION
- Site address
- 201 COLLEGE HWY
- City
- SOUTHWICK
- State
- MA
- ZIP
- 01077
- Mailing
- 26 PARKRIDGE RD. 1B, HAVERHILL, MA 01835
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 50
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.501 B10
- Issued
- May 22, 2024
- Penalty
- Initial $11,292 · Current $11,292
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system: 201 College Hwy, Southwick, MA: On or about December 18, 2023, and at times prior, the employer did not ensure that employees were protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or by an assigned safety monitor while working at a height of approximately 20 feet above a lower level during a commercial solar installation project.
Recent events (1)
- — Z (S) $11292
1926.502 F01
- Issued
- May 22, 2024
- Penalty
- Initial $11,292 · Current $11,292
General-duty citation text
29 CFR 1926.502(f)(1): Warning lines were not erected around all sides of the roof work area: 201 College Hwy, Southwick, MA: On or about December 18, 2023, and at times prior, the employer did not ensure that warning lines were placed around the perimeter of a commercial construction project involving solar panel installation where employees were exposed to fall heights of approximately 20 feet above a lower level.
Recent events (1)
- — Z (S) $11292
1926.502 F01 I
- Issued
- May 22, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(f)(1)(i): When no mechanical equipment was being used the warning line was not erected at least 6 feet (1.8m) from the roof edge: 201 College Hwy, Southwick, MA: On or about December 18, 2023, and at times prior, the employer did not ensure that the warning line system used for fall protection was placed at least six feet from the edge of the roof, exposing employees to fall hazards of 20 feet during a commercial construction project involving solar panel installation.
Recent events (1)
- — Z (S) $0
1926.502 F02
- Issued
- May 22, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(f)(2): Warning line systems did not consist of ropes, wires, or chains: 201 College Hwy, Southwick, MA: On or about December 18, 2023, and at times prior, the employer directed the installation of a warning line system around the perimeter of a roof that consisted of yellow caution tape in lieu of ropes, wires, or chains, and exposed employees to fall heights of 20 feet during a commercial construction project that involved solar panel installation.
Recent events (1)
- — Z (S) $0
1910.178 L06
- Issued
- May 22, 2024
- Abate by
- Jun 27, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): 201 College Hwy, Southwick, MA: On or about December 18, 2023, and at times prior, the employer did not certify that an employee had been trained and evaluated to operate a powered industrial truck while working on a commercial construction project that involved solar panel installation.
Recent events (1)
- — Z (O) $0
1926.503 B01
- Issued
- May 22, 2024
- Abate by
- Jul 11, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: 201 College Hwy, Southwick, MA: On or about December 18, 2023, and at times prior, the employer had not prepared a written certification record of fall protection training which included the name or other identity of the person trained, the signature of the person trained, date(s) the training was completed, and the signature of the person who conducted the training for an employee who was performing solar panel installation work and exposed to fall hazards of approximately 20 feet from a lower level.
Recent events (1)
- — Z (O) $0
More inspections at Invaleon Technologies Corporation
View Invaleon Technologies Corporation's full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347169633.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.