Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,547Inspections Most recent open 2026-09-01 Last loaded 2026-09-04

OSHA Inspection: SLT GROUP VI

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SLT GROUP VI in 5077 S WADSWORTH BLVD, LITTLETON, CO 80123 (NAICS 811111). OSHA activity number 347169823.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch SLT Group VI for free Get an email when a new federal OSHA severe-injury report for SLT Group VI is published. One employer, no account, unsubscribe in one click.
Establishment
SLT GROUP VI
Site address
5077 S WADSWORTH BLVD
City
LITTLETON
State
CO
ZIP
80123
Mailing
5077 S WADSWORTH BLVD, LITTLETON, CO 80123
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
50
Ownership type
Private (A)

2 citations on file for this inspection.

1910.215 B09

Serious Gravity 1 1 instance 10 exposed
Issued
Feb 8, 2024
Penalty
Initial $3,496 · Current $2,098 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  (a) On or before 12/18/2023, the employer did not ensure that the gap between the abrasive wheel and the tongue guard did not exceed on quarter of an inch. This condition exposed employees to flying chips and sparks.
Recent events (2)
  • · I (S) $2097.6
  • · Z (S) $3496

1910.305 B02 I

Other-than-serious 1 instance 5 exposed
Issued
Feb 8, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  (a) On or before 12/18/2023, the employer did not ensure that a junction box with live wires was equipped with a face plate. This condition exposed employees to electric shock and fire hazards.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347169823.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.