Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: SMUCKER'S MEATS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SMUCKER'S MEATS, LLC in 735 PINKERTON ROAD, MOUNT JOY, PA 17552 (NAICS 311611). OSHA activity number 347169849.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Smucker'S Meats, LLC for free Get an email when a new federal OSHA severe-injury report for Smucker'S Meats, LLC is published. One employer, no account, unsubscribe in one click.
Site address
735 PINKERTON ROAD
City
MOUNT JOY
State
PA
ZIP
17552
Mailing
735 PINKERTON ROAD, MOUNT JOY, PA 17552
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311611
Employees
50
Ownership type
Private (A)

7 citations on file for this inspection.

1910.37 A02

Other-than-serious Gravity 1 1 instance 50 exposed
Issued
May 30, 2024
Penalty
Initial $3,496 · Current $0 Reduced
29 CFR  1910.37(a)(2): Exit routes were not arranged so that employees would not have to travel toward a high hazard area, nor was the hazard effectively shielded by suitable partitions or barriers:   a) Customer Service Entrance - Four (4) liquid propane tanks were stored outside the building next to the exterior wall and within approximately 32-inches of the exit door exposing employees to fire and/or explosion hazards, on or about December 14, 2024.  No abatement�certification or�documentation required.
Recent events (2)
  • · I (O) $0
  • · Z (S) $3496

1910.110 F06 II

Other-than-serious Gravity 1 1 instance 50 exposed
Issued
May 30, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.110(f)(6)(ii): Containers were not stored in a suitable enclosure or otherwise protected against tampering:   a) Customer Service Entrance - Four (4) liquid propane tanks were stored outside the building next to the exterior wall without a suitable enclosure or protected against tampering, on or about December 14, 2024.  No abatement�certification or�documentation required.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1910.147 C01

Serious Gravity 1 1 instance 2 exposed
Issued
May 30, 2024
Abate by
Jul 5, 2024
Penalty
Initial $4,113 · Current $3,000 Reduced
29 CFR  1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  a) Cooking Department/Smokehouse Room - On or about December 14, 2023, the employer did not establish an energy control program (lockout/tagout) with procedures for the control of energy, periodic inspections and training to ensure employees were protected before starting servicing or maintenance on machines or equipment. Employees perform cleaning and sanitation activities on a smokehouse with electrical and thermal hazardous energy sources.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $4113

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
May 30, 2024
Abate by
Sep 3, 2024
Penalty
Initial $6,857 · Current $6,000 Reduced
29 CFR  1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a) Cutting Department - A MADO Selekta 3 vertical band saw used to cut meat was not equipped with an adjustable guard to protect employees from accidental contact with the rotating blade, on or about December 14, 2023.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • · I (S) $6000
  • · Z (S) $6857

1910.243 B02

Serious Gravity 1 1 instance 1 exposed
Issued
May 30, 2024
Abate by
Sep 3, 2024
Penalty
Initial $4,113 · Current $3,000 Reduced
29 CFR  1910.243(b)(2): Airhose and hose connections used for conducting compressed air to utilization equipment was not designed for the pressure and service to which they were subjected:  a) Cutting Department - The air hose of a suspended circular meat cutting saw was equipped with a worm-driven hose clamp not designed for use on a pressurized air hose, on or about December 14, 2023.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $4113

1910.305 G01 IV A

Other-than-serious Gravity 1 1 instance 2 exposed
Issued
May 30, 2024
Abate by
Sep 3, 2024
Penalty
Initial $4,113 · Current $0 Reduced
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords�and/or cables�were used�as a�substitute for�the fixed�wiring of�a structure:  a) Cooking Department/Smokehouse Room - An orange 300v triple outlet flexible cord was used in lieu of permanent wiring to energize an FRM-1010 Horizontal Dry Ink Continuous Band Sealer, on or about December 14, 2023.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • · I (O) $0
  • · Z (S) $4113

1910.305 G01 IV B

Other-than-serious Gravity 1 1 instance 2 exposed
Issued
May 30, 2024
Abate by
Sep 3, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors:  a) Cooking Department/Smokehouse Room - An orange 300v triple outlet flexible cord was ran through the ceiling to energize an FRM-1010 Horizontal Dry Ink Continuous Band Sealer, on or about December 14, 2023.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347169849.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.