ARLINGTON, TX —
OSHA Inspection: DOSKOCIL MANUFACTURING INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DOSKOCIL MANUFACTURING INC in 800 W STEPHENS ST., ARLINGTON, TX 76017 (NAICS 326199). OSHA activity number 347174484.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DOSKOCIL MANUFACTURING INC
- Site address
- 800 W STEPHENS ST.
- City
- ARLINGTON
- State
- TX
- ZIP
- 76017
- Mailing
- 2300 EAST RANDOL MILL RD., ARLINGTON, TX 76011
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 563
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.29 B02 I
- Issued
- Jun 13, 2024
- Abate by
- Jul 15, 2024
- Penalty
- Initial $16,131 · Current $6,000 Reduced
General-duty citation text
29 CFR 1910.29(b)(2)(i): The employer did not ensure that guardrails met the requirement that midrails are installed at a height midway between the top edge of the guardrail system and the walking-working surface: On or about December 19, 2023, and at times prior thereto, upper working platforms on the structural foam machines used by employees during mold changeouts had guardrail systems with broken, bent, and/or missing midrails, exposing them to fall hazards greater than four (4) feet.
Recent events (2)
- — I (S) $6000
- — Z (S) $16131
1910.133 A01
- Issued
- Jun 13, 2024
- Abate by
- Jul 15, 2024
- Penalty
- Initial $16,131 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: On or about December 16, 2023, and at times prior thereto, employees were exposed to burn hazards from molten plastic as the employer did not require the use of face shield protection.
Recent events (2)
- — I (O) $3000
- — Z (S) $16131
1910.147 C05 I
- Issued
- Jun 13, 2024
- Abate by
- Jul 15, 2024
- Penalty
- Initial $16,131 · Current $8,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: On or about December 16, 2023, and at times prior thereto, employees required to perform lockout on machinery with multiple energy sources were not provided with enough locks and lockout devices and/or adapters needed to successfully isolate each energy source, exposing employees to amputation, caught-in, struck-by, and thermal hazards.
Recent events (2)
- — I (S) $8000
- — Z (S) $16131
1910.147 F03 I
- Issued
- Jun 13, 2024
- Abate by
- Jul 15, 2024
- Penalty
- Initial $16,131 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew: On or about December 16, 2023, and at times prior thereto, the employer failed to ensure each employee tasked to work as a crew when servicing equipment affixed a lock to each isolating energy device, exposing employees to amputation, caught-in, struck by, and thermal hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $16131
1910.147 C06 I
- Issued
- Jun 13, 2024
- Abate by
- Jul 15, 2024
- Penalty
- Initial $16,131 · Current $6,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about December 16, 2023, and at times prior thereto, a periodic inspection of the energy control procedures for grinders was not conducted at least annually, exposing employees to struck-by, caught-in, and amputation hazards while performing maintenance, servicing, and cleaning operations.
Recent events (2)
- — I (S) $6000
- — Z (S) $16131
1910.147 C07 I
- Issued
- Jun 13, 2024
- Abate by
- Aug 30, 2024
- Penalty
- Initial $16,131 · Current $5,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: On or about December 16, 2023, and at times prior thereto, employees were not trained to recognize the presence of hazardous energy sources and the means to isolate them, exposing employees to struck-by, caught-in, amputation, electric shock, chemical and thermal hazards while performing maintenance, servicing, and cleaning operations.
Recent events (2)
- — I (O) $5500
- — Z (S) $16131
1910.178 L04 III
- Issued
- Jun 13, 2024
- Abate by
- Jul 15, 2024
- Penalty
- Initial $11,524 · Current $5,500 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: On or about December 16, 2023, and at times prior thereto, power industrial truck operators did not receive performance evaluations at least every three (3) years, exposing employees to struck-by hazards.
Recent events (2)
- — I (O) $5500
- — Z (S) $11524
1910.147 C04 I
- Issued
- Jun 13, 2024
- Abate by
- Aug 30, 2024
- Penalty
- Initial $161,323 · Current $90,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about December 16, 2023, at times prior thereto and thereafter, machine-specific energy control procedures were not developed and utilized for the control of hazardous energy, exposing employees to the hazards of unexpected energization, or release of stored energy from machines such as, but not limited to, blow molding machines, structural foam machines, mold injection machines, and sterling machines. Employee exposures include the following instances (a-c): a) Maintenance Technicians performing maintenance and servicing operations were exposed to hazardous energy sources such as, but not limited to, electric, hydraulic, pneumatic, and thermal. b) Tool Setters performing servicing operations were exposed to hazardous energy sources such as, but not limited to, electric, hydraulic, pneumatic, and thermal. c) Process Technicians performing servicing and cleaning operations were exposed to hazardous energy sources such as, but not limited to, electric, hydraulic, pneumatic, and thermal.
Recent events (2)
- — I (S) $90000
- — Z (W) $161323
More inspections at Doskocil Manufacturing INC
View Doskocil Manufacturing INC's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347174484.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.