OSHA Inspection: INDEPENDENT STAVE COMPANY - ZANESVILLE MILL

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of INDEPENDENT STAVE COMPANY - ZANESVILLE MILL in 1519 SHARON AVENUE, ZANESVILLE, OH 43701 (NAICS 321113). OSHA activity number 347174823.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Independent Stave Company - Zanesville Mill — free Get an email when a new federal OSHA severe-injury report for Independent Stave Company - Zanesville Mill is published. One employer, no account, unsubscribe in one click.
Site address
1519 SHARON AVENUE
City
ZANESVILLE
State
OH
ZIP
43701
Mailing
1519 SHARON AVENUE, ZANESVILLE, OH 43701
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
55
Ownership type
A

2 citations on file for this inspection.

1910.147 D

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 9, 2024
Abate by
Feb 28, 2024
Penalty
Initial $16,131 · Current $16,131
29 CFR  1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) was not done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6):  a. On or about December 19, 2023, employees were exposed to machine hazards associated with moving parts during servicing and maintenance of the Log Roller Machine. The employer failed to implement energy control application steps as the machine was not shut down or turned off to performing the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (1)
  • — Z (S) $16131

1910.95 I03

Other-than-serious 1 instance 20 exposed
Issued
Feb 9, 2024
Abate by
Feb 28, 2024
Penalty
Initial $0 · Current $0

Hazardous substances 81108111

29 CFR  1910.95(i)(3):Employees shall be given the opportunity to select their hearing protectors from a variety of suitable hearing protectors provided by the employer.  a. On or before January 3, 2024, the employer did not provide more than one hearing protector option to employees who were exposed to noise above the Action Level and the Permissible Exposure Limit.