Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TEXAS PIPE AND SUPPLY COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TEXAS PIPE AND SUPPLY COMPANY in 2330 HOLMES RD, HOUSTON, TX 77051 (NAICS 326122). OSHA activity number 347175309.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Texas Pipe and Supply Company — free Get an email when a new federal OSHA severe-injury report for Texas Pipe and Supply Company is published. One employer, no account, unsubscribe in one click.
Site address
2330 HOLMES RD
City
HOUSTON
State
TX
ZIP
77051
Mailing
2330 HOLMES RD, HOUSTON, TX 77051
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326122
Employees
120
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 1 instance 2 exposed
Issued
May 29, 2024
Penalty
Initial $11,524 · Current $6,914 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:  On December 15, 2023, and times prior to, at the facility, where the employer did not have specific energy control procedures for the shutting down, isolating, blocking and securing the HEM Saw Sidewinder.
Recent events (2)
  • — I (S) $6914.4
  • — Z (S) $11524

1910.147 C04 II D

Serious Gravity 5 1 instance 2 exposed
Issued
May 29, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, and other energy control:  On December 15, 2023, and times prior to, at the facility, where the employer did not have specific energy control procedures for testing a machine or equipment to determine and verify the effectiveness of lockout devices, and other energy control for the HEM Saw Sidewinder.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 5 1 instance 2 exposed
Issued
May 29, 2024
Abate by
Jul 3, 2024
Penalty
Initial $11,524 · Current $6,914 Reduced
29 CFR  1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:  On December 20, 2023, and times prior to, in the shop area, where authorized employees did not receive training for hazardous energy sources, the type and magnitude of the energy available, and the methods and means necessary for energy isolation for the HEM Saw Sidewinder.
Recent events (2)
  • — I (S) $6914.4
  • — Z (S) $11524

1910.212 A01

Serious Gravity 10 2 instances 2 exposed
Issued
May 29, 2024
Abate by
Jun 24, 2024
Penalty
Initial $16,131 · Current $9,679 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   a) On December 15, 2023, and times prior to, in the TPS01 Shop, on the HEM Saw Sidewinder, there was no guard around the arm height limit rod, Upper limit stop collar, and Arm Limit Switch Block.  b) On December 15, 2023, and times prior to, in the TPS01 Shop, the HEM Saw Sidewinder sliding blade was not guarded.
Recent events (2)
  • — I (S) $9678.6
  • — Z (S) $16131

1904.39 A02

Other-than-serious 1 instance 1 exposed
Issued
May 29, 2024
Penalty
Initial $11,524 · Current $6,914 Reduced
29 CFR  1904.39(a)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye.  a) On or about December 15, 2023, where a work related amputation was not reported to OSHA within 24 hours.
Recent events (2)
  • — I (O) $6914.4
  • — Z (O) $11524

View Texas Pipe and Supply Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347175309.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.