Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COUNTRY JUNCTION SERVICE TEAM

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COUNTRY JUNCTION SERVICE TEAM in 1965 FORREST INN ROAD, PALMERTON, PA 18071 (NAICS 493110). OSHA activity number 347175838.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Country Junction Service Team — free Get an email when a new federal OSHA severe-injury report for Country Junction Service Team is published. One employer, no account, unsubscribe in one click.
Site address
1965 FORREST INN ROAD
City
PALMERTON
State
PA
ZIP
18071
Mailing
6565 INTERCHANGE ROAD, LEHIGHTON, PA 18235
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
22
Ownership type
A

28 citations on file for this inspection.

1910.28 B11 II

Serious Gravity 5 4 instances 5 exposed
Issued
Apr 5, 2024
Abate by
May 1, 2024
Penalty
Initial $3,687 · Current $3,000 Reduced
29 CFR 1910.28(b)(11)(ii): The employer did not ensure that each flight of stairs having at least 3 treads and at least 4 risers was equipped with stair rail systems and handrails as described in 29 CFR 1910.28 Table D-2-Stairway Handrail Requirements:  (a) Hospital Area - On or about December 20, 2023, employees accessing the mezzanine above the hospital area were exposed to a fall hazard in that the enclosed stairs did not have a handrail on each side.  (b) Furniture Preparation Area - On or about December 20, 2023, employees accessing the mezzanine above the furniture preparation area were exposed to a fall hazard in that the stairs were open on one side and did not have a stair rail system with a handrail on the open side and one handrail on the enclosed side.   (c) Near the Office - On or about December 20, 2023, employees accessing the mezzanine above the office were exposed to a fall hazard in that the top of the stairs were open on one side and did not have a stair rail system with handrail on the open side.  (d) On Mezzanine - On or about December 20, 2023, employees using the stairs on the mezzanine were exposed to a fall hazard in that the stairs were enclosed and did not have a handrail on each side.   Abatement Certification Required.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3687

1910.29 F05

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 5, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.29(f)(5): The employer did not ensure that handrails have the shape and dimension necessary so that employees can grasp the handrail firmly:  (a) Hospital Area - On or about December 20, 2023, employees accessing the mezzanine in the hospital area were exposed to a fall hazard because the stairs were installed with a handrail that could not be firmly grasped.   Certification Not Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.29 B10

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 5, 2024
Penalty
Initial $4,610 · Current $3,500 Reduced
29 CFR 1910.29(b)(10): The employer did not ensure that when guardrail systems were used at hoist areas, a removable guardrail section, consisting of a top rail and midrail, were placed across the access opening between guardrail sections when employees are not performing hoisting operations:  a) Mezzanine - On or about December 20, 2024, employees working near hoist areas on the mezzanine were exposed to fall hazards of up to twelve (12) feet because the single chain did not provide a level of safety equivalent to guardrails.  Certification not required.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $4610

1910.37 A03

Serious Gravity 1 2 instances 22 exposed
Issued
Apr 5, 2024
Penalty
Initial $2,765 · Current $2,200 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  (a) Furniture Preparation Area - On or about December 20, 2023, employees were exposed to a fire hazard because an emergency exit route was obstructed by a cardboard box and an electrical cord.   (b) Flooring Department - On or about December 20, 2023, employees were exposed to a fire hazard because an emergency exit route was obstructed by a section of a steel racking system.  Certification Not Required.
Recent events (2)
  • — I (S) $2200
  • — Z (S) $2765

1910.37 B06

Serious Gravity 1 2 instances 22 exposed
Issued
Apr 5, 2024
Penalty
Initial $2,765 · Current $2,200 Reduced
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:  (a) Furniture Preparation Area - On or about December 20, 2023, employees were exposed to a fire hazard because an emergency exit sign was not illuminated.  (b) Flooring Department - On or about December 20, 2023, employees were exposed to a fire hazard because an emergency exit sign was not illuminated.  Certification Not Required.
Recent events (2)
  • — I (S) $2200
  • — Z (S) $2765

1910.106 E02 II B 1

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 5, 2024
Penalty
Initial $6,452 · Current $5,800 Reduced
29 CFR 1910.106(e)(2)(ii)(b)(1): The quantity of liquid that was located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building exceeded 25 gallons of Class IA liquids in containers:  (a) Repair Area - On or about December 20, 2024, employees in the repair area were exposed to a fire hazard because approximately fifty-seven (57) gallons of a category 1 flammable liquid were stored outside of a storage cabinet.  Certification Not Required.
Recent events (2)
  • — I (S) $5800
  • — Z (S) $6452

1910.132 D01

Serious Gravity 10 4 instances 2 exposed
Issued
Apr 5, 2024
Abate by
Apr 17, 2024
Penalty
Initial $6,452 · Current $5,800 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment:  (a) Repair Area - On or about December 20, 2023, an employee required to handle hazardous chemicals was exposed to chemical burns and the employer did not assess the workplace to determine if protective eyewear was needed.   (b) Repair Area - On or about December 20, 2023, an employee required to operate a table saw and chop saw was exposed to struck-by hazards and the employer did not assess the workplace to determine if protective eyewear was needed.   (c) Repair Area - On or about December 20, 2023, an employee required to handle hazardous chemicals was exposed to chemical burns and the employer did not assess the workplace to determine if hand protection was needed.   (d) Battery Refill Area - On or about December 20, 2023, an employee required to handle corrosive chemicals while refiling forklift batteries was exposed to chemical burn hazards because the employer did not assess the workplace to determine if protective eyewear was needed.   Abatement Certification and Documentation Required.
Recent events (2)
  • — I (S) $5800
  • — Z (S) $6452

1910.133 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 5, 2024
Abate by
Apr 17, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  (a) Repair Area - On or about December 20, 2023, an employee was required to handle chemicals which could cause serious eye damage, including those found in M102-0420 such as: isobutyl acetate, ethyl acetate, propane, acetone, n-butane, toluene, butanol, cellulose nitrate, cellulose ester, butyl cellosolve, isopropanol, and n-butyl acetate and were not provided with protective eyewear.  Abatement Certification and Documentation Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.138 A

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 5, 2024
Abate by
Apr 17, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion:  (a) Repair Area - On or about December 20, 2023, an employee was required to handle hazardous chemicals which could cause chemical burns, including those found in M102-0420 such as: isobutyl acetate, ethyl acetate, propane, acetone, n-butane, toluene, butanol, cellulose nitrate, cellulose ester, butyl cellosolve, isopropanol, and n-butyl acetate and were not provided with appropriate hand protection
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 5, 2024
Abate by
May 15, 2024
Penalty
Initial $4,610 · Current $3,500 Reduced
29 CFR 1910.134(a)(2): The employer did not establish and maintain a respiratory protection program which included the requirements outlined in 29 CFR 1910.134(c):  (a) Repair Area - On or about December 20, 2023, an employee was required to handle hazardous chemicals including but not limited to, those found in M102-0420 such as: isobutyl acetate, ethyl acetate, propane, acetone, n-butane, toluene, butanol, cellulose nitrate, cellulose ester, butyl cellosolve, isopropanol, and n-butyl acetatein and the employer did not establish a respiratory protection program.  Abatement Certification Required.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $4610

1910.134 C02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 5, 2024
Abate by
May 15, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  (a) Repair Area - The employer determined that voluntary respirator use was permissible for employees handling chemicals including, but not limited to, those found in M102-0420 such as: isobutyl acetate, ethyl acetate, propane, acetone, n-butane, toluene, butanol, cellulose nitrate, cellulose ester, butyl cellosolve, isopropanol, and n-butyl acetate and did not provide an employee with the information contained in Appendix D to 29 CFR 1910.134.  Abatement Certification Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 D01 III

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 5, 2024
Abate by
May 15, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  (a) Repair Area - On or about December 20, 2023, an employee was required to handle hazardous chemicals including but not limited to, those found in M102-0420 such as: isobutyl acetate, ethyl acetate, propane, acetone, n-butane, toluene, butanol, cellulose nitrate, cellulose ester, butyl cellosolve, isopropanol, and n-butyl acetatein and the employer did not evaluate the respiratory hazard.  Abatement Certification Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 5, 2024
Abate by
May 15, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  (a) Repair Area - On or about December 20, 2023, an employee voluntarily wore an elastomeric respirator while they handled hazardous chemicals including, but not limited to, those found in M102-0420 such as: isobutyl acetate, ethyl acetate, propane, acetone, n-butane, toluene, butanol, cellulose nitrate, cellulose ester, butyl cellosolve, isopropanol, and n-butyl acetatein and was not medically evaluated to ensure they could safely wear the respirator.  Abatement Certification Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 5, 2024
Penalty
Initial $4,610 · Current $3,500 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  a) Battery Refill Area - On or about December 20, 2023, an employee was required to handle corrosive chemicals, including lithium-ion battery electrolyte (Sulfuric Acid), and was not provided with an emergency eyewash station in the work area for immediate emergency use.  Certification Not Required.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $4610

1910.303 B02

Serious Gravity 5 1 instance 22 exposed
Issued
Apr 5, 2024
Penalty
Initial $4,610 · Current $3,500 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) Main Warehouse - On or about December 20, 2023, employees working in the main warehouse were exposed to electrical hazards in that numerous extension cords were daisy chained into each other and into relocatable power taps.  Certification Not Required
Recent events (2)
  • — I (S) $3500
  • — Z (S) $4610

1910.305 G01 IV A

Serious Gravity 5 1 instance 22 exposed
Issued
Apr 5, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) Main Warehouse - On or about December 20, 2023, employees working in the main warehouse were exposed to electrical hazards in that extension cords were used as a substitute for the fixed wiring of shop lights, dock lights, industrial fans, radios, computers, a chop saw, and other equipment.  Certification Not Required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV B

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 5, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors:  (a) Hospital Area - On or about December 20, 2023, employees working in the hospital area were exposed to electrical hazards in that extension cords were run through holes in the wall to power shop lights, radios, a computer, portable battery chargers, and other equipment.  Certification Not Required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV D

Serious Gravity 5 1 instance 22 exposed
Issued
Apr 5, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces:  (a) Main Warehouse - On or about December 20, 2023, employees working in the main warehouse were exposed to electrical hazards in that extension cords were attached to building surfaces before powering shop lights, radios, a computer, portable battery chargers, and other equipment.  Certification Not Required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 5 1 instance 22 exposed
Issued
Apr 5, 2024
Penalty
Initial $4,610 · Current $3,500 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  (a) Main Warehouse - On or about December 20, 2023, employees working in the main warehouse were exposed to electrical hazards in that extension cords powering shop lights, dock lights, industrial fans, radios, computers, a chop saw, and other equipment were not visually inspected for damage  Certification Not Required
Recent events (2)
  • — I (S) $3500
  • — Z (S) $4610

1910.1200 E01

Serious Gravity 10 1 instance 22 exposed
Issued
Apr 5, 2024
Abate by
May 15, 2024
Penalty
Initial $6,452 · Current $3,500 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  (a) Main Warehouse - On or about December 20, 2023, the employer did not develop a written hazard communication program for employees exposed to chemicals such as, but not limited to, those found in M102-0420: isobutyl acetate, ethyl acetate, propane, acetone, n-butane, toluene, butanol, cellulose nitrate, cellulose ester, butyl cellosolve, isopropanol, and n-butyl acetate  Abatement Certification and Documentation Required.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $6452

1910.1200 G01

Serious Gravity 10 1 instance 22 exposed
Issued
Apr 5, 2024
Abate by
May 15, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:  (a) Main Warehouse - On or about December 20, 2023, employees were required to use and work in proximity to hazardous chemicals such as, but not limited to, those found in M102-0420: isobutyl acetate, ethyl acetate, propane, acetone, n-butane, toluene, butanol, cellulose nitrate, cellulose ester, butyl cellosolve, isopropanol, and n-butyl acetate and were not provided safety data sheets.  Abatement Certification and Documentation Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 10 1 instance 22 exposed
Issued
Apr 5, 2024
Abate by
May 15, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:   (a) Main Warehouse - On or about December 20, 2023, employees were required to use and work in proximity to hazardous chemicals such as, but not limited to, those found in M102-0420: isobutyl acetate, ethyl acetate, propane, acetone, n-butane, toluene, butanol, cellulose nitrate, cellulose ester, butyl cellosolve, isopropanol, and n-butyl acetate and were not trained on the chemical hazards.   Abatement Certification and Documentation Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.38 B

Other-than-serious 1 instance 22 exposed
Issued
Apr 5, 2024
Abate by
May 15, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review:  (a) Facility Wide - On or about December 20, 2023, the employer did not maintain a written emergency action plan at the site.   Abatement Certification Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.39 B

Other-than-serious 1 instance 22 exposed
Issued
Apr 5, 2024
Abate by
May 1, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.39(b): A fire prevention plan was not in writing, kept in the workplace, and made available to employees for review:  (a) Facility Wide - On or about December 20, 2023, the employer did not maintain a written fire prevention plan at the site.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 C01

Other-than-serious 1 instance 22 exposed
Issued
Apr 5, 2024
Abate by
Apr 17, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  (a) Facility Wide - On or about December 20, 2023, employees at the site were exposed to fire hazards because portable fire extinguishers were not mounted and identified.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 1 instance 22 exposed
Issued
Apr 5, 2024
Abate by
Apr 17, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  (a) Facility Wide - On or about December 20, 2023, the employer did not visually inspect the portable fire extinguishers at least monthly.  Abatement Certification Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 L04 III

Other-than-serious 1 instance 13 exposed
Issued
Apr 5, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  (a) Facility Wide - On or about December 20, 2023, employees were required to operate forklifts and their performance had not been evaluated at least once every three years.  Certification Not Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 L06

Other-than-serious 1 instance 13 exposed
Issued
Apr 5, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  (a) Facility Wide - On or about December 20, 2023, the employer did not certify that employees required to operate forklifts had been trained and evaluated prior to operating those powered industrial trucks.  Certification Not Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347175838.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.