Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMSTERDAM PRINTING & LITHO, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AMSTERDAM PRINTING & LITHO, INC in 166 WALLINS CORNERS ROAD, AMSTERDAM, NY 12010 (NAICS 323111). OSHA activity number 347178790.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Amsterdam Printing & Litho, INC — free Get an email when a new federal OSHA severe-injury report for Amsterdam Printing & Litho, INC is published. One employer, no account, unsubscribe in one click.
Site address
166 WALLINS CORNERS ROAD
City
AMSTERDAM
State
NY
ZIP
12010
Mailing
166 WALLINS CORNERS ROAD, AMSTERDAM, NY 12010
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
200
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 7, 2024
Abate by
Jun 17, 2024
Penalty
Initial $10,372 · Current $10,372
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items A - D of this section:   a)  Calendar Area, Hot Stamper #21 - On or about December 20, 2023 and at times prior thereto, the employer did not have specific procedural steps to control hazardous energy to hot stampers prior to removing the guarding and/or clearing jams on foil rolls.
Recent events (1)
  • — Z (S) $10372

1910.147 C06 I

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 7, 2024
Penalty
Initial $10,372 · Current $10,372
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) Calendar Area, Hot Stamper #21 - On or about December 20, 2023 and at times prior thereto, the employer did not perform at least annual inspections and update the program as needed.
Recent events (1)
  • — Z (S) $10372

1910.212 A01

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 7, 2024
Abate by
Jun 17, 2024
Penalty
Initial $10,372 · Current $10,372
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) Calendar Area, Hot Stamper #21 - On or about December 20, 2023 and at times prior thereto, employees were exposed to the top of the stampers moving parts when fixing wrinkles in the foil roll.