FULTON, MS —
OSHA Inspection: DANIEL HEALTH CARE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DANIEL HEALTH CARE, INC. in 804 SOUTH ADAMS ST., FULTON, MS 38843 (NAICS 623311). OSHA activity number 347180226.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DANIEL HEALTH CARE, INC.
- Site address
- 804 SOUTH ADAMS ST.
- City
- FULTON
- State
- MS
- ZIP
- 38843
- Mailing
- P.O. DRAWER 337, FULTON, MS 38843
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 623311
- Employees
- 23
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C01
- Issued
- Feb 8, 2024
- Abate by
- Mar 4, 2024
- Penalty
- Initial $6,222 · Current $3,733 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. (a) Facility - On or about December 20, 2023 the employer did not have an energy control program for employees that perform servicing and maintenance on such as but not limited to, Universal hot water heaters with energy control procedures, documented training, and periodic inspections exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $3733.2
- — Z (S) $6222
1910.303 F02
- Issued
- Feb 8, 2024
- Abate by
- Mar 11, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2):Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident. (a) Facility - On or about December 20, 2023 the employer did not identify circuit breakers exposing employees to electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Daniel Health Care, INC.
View Daniel Health Care, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 623311)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347180226.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.