OSHA Inspection: B. L. ATHERTON PLUMBING, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of B. L. ATHERTON PLUMBING, LLC in 3028 W FARMINGTON ROAD, WEST PEORIA, IL 61604 (NAICS 238220). OSHA activity number 347189557.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch B. L. Atherton Plumbing, LLC — free Get an email when a new federal OSHA severe-injury report for B. L. Atherton Plumbing, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3028 W FARMINGTON ROAD
City
WEST PEORIA
State
IL
ZIP
61604
Mailing
2200 E WAR MEMORIAL DRIVE, PEORIA, IL 61614
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.651 K01

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 24, 2024
Abate by
Feb 23, 2024
Penalty
Initial $4,839 · Current $2,420 Reduced
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions:     On or about January 2, 2023, the employer did not perform an inspection of the trench to ensure that an effective protective system was in place prior to permitting employees to work in the trench to repair a sanitary pipe.
Recent events (2)
  • — I (S) $2420
  • — Z (S) $4839

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 24, 2024
Penalty
Initial $4,839 · Current $0 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c):  On or about January 2, 2023, an employee was working on a broken sewer line while in a seven foot, vertical cut trench and the employee was not protected from cave-ins by an adequate protective system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4839

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347189557.