STURTEVANT, WI —
OSHA Inspection: ECT INTERNATIONAL INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ECT INTERNATIONAL INC. in 8425 CORLISS AVENUE, STURTEVANT, WI 53177 (NAICS 236118). OSHA activity number 347197626.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ECT INTERNATIONAL INC.
- Site address
- 8425 CORLISS AVENUE
- City
- STURTEVANT
- State
- WI
- ZIP
- 53177
- Mailing
- N63 W23217 MAIN STREET #200, SUSSEX, WI 53089
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 27
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.403 I02 I
- Issued
- May 21, 2024
- Penalty
- Initial $4,113 · Current $0 Reduced
General-duty citation text
29 CFR 1926.403(i)(2)(i):Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by elevation of 8 feet (2.44 m) or more above the floor or other working surface and so installed as to exclude unqualified persons: (a) On or about January 5, 2024, the employer did not ensure live wires were above 8 feet from walking/working surface in building A on the 3rd floor on the east end near the elevator and stairwell. This exposed employees to an electrical shock hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $4113
1926.1052 C01 I
- Issued
- May 21, 2024
- Penalty
- Initial $4,113 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(i):Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: (a) On or about January 5, 2024, the employer did ensure that the east stairways in Building A had at least one handrail installed presenting a fall hazard to employees. (b) On or about January 5, 2024, the employer did ensure that the west stairways in Building A had at least one handrail installed presenting a fall hazard to employees. (c) On or about January 5, 2024, the employer did ensure that the east stairways in Building D had at least one handrail installed presenting a fall hazard to employees.
Recent events (2)
- — I (S) $0
- — Z (S) $4113
More inspections at ECT International INC.
View ECT International INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236118)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347197626.