OSHA Inspection: PETERSON COMPANY

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of PETERSON COMPANY in 10700 50TH AVE., WHEAT RIDGE, CO 80033 (NAICS 332312). OSHA activity number 347202772.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Peterson Company — free Get an email when a new federal OSHA severe-injury report for Peterson Company is published. One employer, no account, unsubscribe in one click.
Establishment
PETERSON COMPANY
Site address
10700 50TH AVE.
City
WHEAT RIDGE
State
CO
ZIP
80033
Mailing
10700 50TH AVE., WHEAT RIDGE, CO 80033
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
25
Ownership type
A

17 citations on file for this inspection.

5(a)(1)

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 26, 2024
Abate by
Sep 3, 2024
Penalty
Initial $4,839 · Current $2,420 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees who were exposed to struck-by and crushing hazards:  a) On or about January 09, 2024, and at times prior, employees were exposed to struck-by and crushing hazards from hoists that were in regular use and were not inspected frequently to ensure they were in safe working order in that the hook safety latches were broken, pendants were broken exposing wiring, and taped together, hoist up button was broken and missing directional indication, wiring festoon was broken, causing electrical wire to hang.  Abatement Note:  Among other methods, one feasible and acceptable abatement method to correct this hazard is to inspect the hoists frequently by the operators or designated personnel, and periodically by a designated person, in accordance with ANSI/ASME B30.16, Overhead Hoists (Underhung), Section 16-2.1 - Inspections.
Recent events (2)
  • — I (S) $2420
  • — Z (S) $4839

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 26, 2024
Abate by
Oct 31, 2024
Penalty
Initial $8,067 · Current $4,040 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  a) On or about January 09, 2024, and at times prior, the employer did not establish a program of an energy control procedure, employee training, and periodic inspections to ensure that employees performing servicing and maintenance such as changing dies on equipment including, but not limited to, the Uni Hydro Punch Press.  The employer did not ensure that employees were protected from the unexpected energization, startup or release of stored energy that could cause injury exposing employees to crushing and amputation hazards.
Recent events (2)
  • — I (S) $4040
  • — Z (S) $8067

1910.178 L01 I

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 26, 2024
Abate by
Sep 3, 2024
Penalty
Initial $4,839 · Current $2,420 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  a) On or about January 09, 2024, and at times prior, the employer allowed employees to operate powered industrial trucks without successful completion of training and evaluation in paragraph(l) exposing employees to crushing and struck by hazards.
Recent events (2)
  • — I (S) $2420
  • — Z (S) $4839

1910.178 P01

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 26, 2024
Abate by
Jul 25, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.178(p)(1): The employer did not ensure that powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition:  a) On or about January 09, 2024, and at times prior, the Hyster H60XM had large chunks missing out of the tires and abrasions on the hydraulic lines making it unsafe to operate but had not removed from service exposing employees to tip over hazards from instability and struck by hazards from damage to hydraulic lines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 4 instances 3 exposed
Issued
Jun 26, 2024
Abate by
Oct 1, 2024
Penalty
Initial $9,680 · Current $4,840 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a) On or about January 09, 2024, and at times prior, employees were exposed to caught in hazards in that Sears Craftsman 20in 20 hp industrial rated drill press chuck was not guarded.  b) On or about January 09, 2024, and at times prior, employees were exposed to amputation hazards in that the Cincinatti 1812 Metal Sheer did not have finger guards or other guarding to prevent employees from having any part of their body in the danger zone during the operating cycle exposing employees to amputation hazards.  c) On or about January 09, 2024, and at times prior, employees were exposed to amputation hazards when the Trennjaeger cold saw model # PMC 8, serial # GG 861 was left running without point of operation guards.  d) On or about January 09, 2024, and at times prior, the employer did not provide and ensure point of operation guards were used and properly applied when employees operated the Uni Hydro 42-ton Model #42-14, Serial # 1P-3159X to punch parts exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $4840
  • — Z (S) $9680

1910.252 A01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 26, 2024
Abate by
Sep 3, 2024
Penalty
Initial $6,453 · Current $3,220 Reduced
29 CFR 1910.252(a)(1)(i): When the object to be welded or cut could not be readily moved, all movable fire hazards in the vicinity were not taken to a safe place:  a) On or about January 09, 2024, and at times prior, cardboard boxes of flammable aerosol paint cans of Quick Color were kept in welding areas, along with flammable aerosol cans including but not limited to Brite Zinc, and Quick Color which were stored on the work cart in the welding area, exposing employees to fire hazards.
Recent events (2)
  • — I (S) $3220
  • — Z (S) $6453

1910.252 A02 IX

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 26, 2024
Abate by
Oct 31, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.252(a)(2)(ix): Where cutting or welding was done near walls, partitions, ceiling or roof of combustible construction, fire-resistant shields or guards were not provided to prevent ignition:  a) On or about January 09, 2024, and at times prior, employees were authorized by management to weld adjacent to combustible building walls of plywood without the use of fire-resistant shields, or guards to prevent ignition.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.252 A02 XIII A

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 26, 2024
Abate by
Sep 3, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.252(a)(2)(xiii)(A): The employer did not recognize its responsibility for the safe usage of cutting or welding equipment, based on fire potentials of plant facilities, and establish areas for cutting and welding, and procedures for cutting and welding, in other areas:  a) On or about January 09, 2024, and at times prior, the employer did not recognize its responsibility for safe usage of cutting and welding equipment based on fire potentials of plant facilities and establish areas for cutting and welding in that, the area the employer provided employees for welding contained fire hazards including, but not limited to, plywood on the walls, cardboard on the walls, storage of acetylene and oxygen cylinders in the welding area, storage of flammable aerosol cans in the welding area which exposed employees were exposed to fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 26, 2024
Abate by
Jul 25, 2024
Penalty
Initial $4,839 · Current $2,420 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  a) On or about January 09, 2024, and at times prior, acetylene and oxygen cylinders were stored on a cart and were not separated by minimum distance of 20 feet, or by a noncombustible barrier at least 5ft high with fire resistance rating of at least one-half hour, exposing employees to fire hazards.
Recent events (2)
  • — I (S) $2420
  • — Z (S) $4839

1910.253 B05 II I

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 26, 2024
Abate by
Jul 25, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(5)(ii)(I): Cylinders were not kept far enough away from the actual welding or cutting operation so that sparks, hot slag, or flame would not reach them:  a) On or about January 09, 2024, and at times prior, acetylene and oxygen cylinders were stored in the welding area, less than 10 feet away from where welding activities were being performed and were not kept far enough away from actual welding so that sparks, hot slag or flame would not reach them exposing employees to fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B05 II G

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 26, 2024
Abate by
Jul 25, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(5)(ii)(G): Cylinder valves were not closed when the work was finished:  a) On or about January 09, 2024, at times prior, acetylene and oxygen cylinders were stored with open valves and were not closed when the work was finished.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C

Other-than-serious 1 instance 3 exposed
Issued
Jun 26, 2024
Abate by
Sep 3, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use:  a) On or about January 09, 2024, and at times prior, the employer did not develop and implement a written respiratory protection program when requiring employees to wear half-mask tight-fitting respirators with P100 cartridges when welding.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 G01 I A

Other-than-serious 1 instance 3 exposed
Issued
Jun 26, 2024
Abate by
Sep 3, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:  a) On or about January 09, 2024, and at times prior, employees required to wear half mask tight fitting respirators were allowed by the employer to have facial hair that interfered with the seal on the half mask tight fitting respirator.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 K

Other-than-serious 1 instance 3 exposed
Issued
Jun 26, 2024
Abate by
Sep 3, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary:  a) On or about January 09, 2024, and at times prior, the employer did not provide comprehensive understandable training for employees required to wear tight-fitting half-mask respirators when welding.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.212 B

Other-than-serious 1 instance 3 exposed
Issued
Jun 26, 2024
Abate by
Jul 25, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  a) On or about January 09, 2024, and at times prior, employees were exposed to struck-by hazards while using Sears Craftsman 20in 20hp Industrial Rated Drill Press that is designed for a fixed location but was not bolted to the floor to prevent tipping.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 3 exposed
Issued
Jun 26, 2024
Abate by
Sep 3, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program that included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):  a) On or about January 09, 2024, and at times prior, the employer did not implement a written hazard communication program that included the requirements outlined when employees used hazardous chemicals including but not limited to Quick Color, Brite Zinc, and Radnor Anti Spatter which include physical and health hazards, but not limited to, flammable, reproductive toxicity, specific organ toxicity, and eye irritation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.252 C01 IV

Other-than-serious 1 instance 3 exposed
Issued
Jun 26, 2024
Abate by
Sep 3, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.252(c)(1)(iv): The employer did not include the potentially hazardous materials employed in fluxes, coatings, coverings, and filler metals, all of which are potentially used in welding and cutting, in the program established to comply with Hazard Communication Standard (HCS) (sec. 1910.1200):  a) On or about January 09, 2024, and at times prior, the employer did not include hazardous materials in coatings, filler metals and wire used in welding in the program established to comply with Hazard Communication including but not limited to zinc coating, aluminum, and manganese.