Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARCHITECTURAL DOORS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ARCHITECTURAL DOORS, INC. in 4199 ONEIDA ST. BLDG A, DENVER, CO 80207 (NAICS 321911). OSHA activity number 347219503.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Architectural Doors, INC. — free Get an email when a new federal OSHA severe-injury report for Architectural Doors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4199 ONEIDA ST. BLDG A
City
DENVER
State
CO
ZIP
80207
Mailing
3900 HOLLY STREET, DENVER, CO 80207
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321911
Employees
2
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 9, 2024
Abate by
Jan 6, 2025
Penalty
Initial $6,452 · Current $3,226 Reduced

Hazardous substances E200

OSH ACT of 1970 Section (5)(a)(1):Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that caused or were likely to cause death or serious physical harm in that employees were exposed to combustible dust explosion, deflagration, or other fire hazards while working at or near dust collection system which were not adequately designed to prevent or minimize employee exposure in the event of a deflagraion or other uncontrolled fire event:  a) CNC Area, Architectural Door Machine 4199 Oneida St. Bldg A, Denver, CO 80207; On or about January 19, 2024, and at times prior, employees in the wood shop were operating and working within proximity of woodworking equipment that was not serviced by any type of dust collection system nor was the area cleared of dust daily or more frequently. Employees were exposed to explosion hazards due to the design, construction, location, and maintenance of a dust collector system that collected explosive wood dust and did not adhere to one of the following:   1. Located outside of the building.  2. Equipped with listed deflagration suppression system.  3. Equipped with deflagration relief vents with relief pipes extending to safe areas outside the building.  4. Equipped with deflagration relief vents exhausting through listed flame-quenching devices. 5. The collected dust is removed daily or more frequently.  b) CNC Area, Edge Machine 4199 Oneida St. Bldg A, Denver, CO 80207; On or about January 19, 2024, and at times prior, employees in the wood shop were operating and working within proximity of woodworking equipment which was serviced by a double filter and bag dust collector system located inside of the building. Employees were exposed to explosion hazards due to the design, construction, location, and maintenance of a dust collector system that collected explosive wood dust and did not adhere to one of the following:   1. Located outside of the building.  2. Equipped with listed deflagration suppression system.  3. Equipped with deflagration relief vents with relief pipes extending to safe areas outside the building.  4. Equipped with deflagration relief vents exhausting through listed flame-quenching devices.  c) Table Saw Area, 4199 Oneida St. Bldg A, Denver, CO 80207; Employees operating and working within proximity of a woodworking table saw  which was serviced by an single filter and bag dust collector system located inside of the building. Employees were exposed to fire hazards due to the design, construction, location, and maintenance of a dust collector system that collected combustible wood dust and did not adhere to all of the following:   1. Located outside of the building.  2. Equipped with listed deflagration suppression system.  3. Equipped with deflagration relief vents with relief pipes extending to safe areas outside the building.  4. Equipped with deflagration relief vents exhausting through listed flame-quenching devices. 5. The collected dust is removed daily or more frequently.
Recent events (2)
  • — I (S) $3226
  • — Z (S) $6452

1910.22 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 9, 2024
Abate by
Jul 24, 2024
Penalty
Initial $4,610 · Current $2,305 Reduced

Hazardous substances E200

29 CFR  1910.22(a)(1): 29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition.  (a) Architectural Doors, Inc., Woodshop; On and around January 19, 2024, and at times prior, employees were exposed to slips, trips and fall hazards due excessive buildup of dust throughout the shop.
Recent events (2)
  • — I (S) $2305
  • — Z (S) $4610

View Architectural Doors, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347219503.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.