Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALEXANDER GREY CUSTOM CABINETS

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ALEXANDER GREY CUSTOM CABINETS in 10930 GABRIEL'S PLACE, SAN ANTONIO, TX 78217 (NAICS 337110). OSHA activity number 347219941.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alexander Grey Custom Cabinets — free Get an email when a new federal OSHA severe-injury report for Alexander Grey Custom Cabinets is published. One employer, no account, unsubscribe in one click.
Site address
10930 GABRIEL'S PLACE
City
SAN ANTONIO
State
TX
ZIP
78217
Mailing
10930 GABRIEL'S PLACE, SAN ANTONIO, TX 78217
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
337110
Employees
5
Ownership type
A

12 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 30, 2024
Abate by
Jun 3, 2024
Penalty
Initial $2,074 · Current $2,074
29 CFR  1910.22(a)(1): 29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition.   Woodshop area: On or about January 19, 2024, and at times prior, employees were exposed to fire, or explosive hazards when working around accumulations of explosive wood dust in the shop area and electrical panels.
Recent events (1)
  • — Z (S) $2074

1910.107 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 30, 2024
Penalty
Initial $2,765 · Current $2,765
29 CFR  1910.107(b)(1): The spraybooth�was not�substantially constructed�of steel,�securely and�rigidly supported,�or of�concrete or�masonry.  Spray area: On or about January 19, 2024, and at times prior thereto, employees were exposed to fire hazards when using a spray area that was made of plastic walls from a tent while painting cabinets.
Recent events (1)
  • — Z (S) $2765

1910.107 D02

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 30, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.107(d)(2):All spraying areas were not provided with mechanical ventilation adequate to remove flammable vapors, mists, or powders to a safe location and to confine and control combustible residues so that life was not endangered.  Spray area: On or about January 19, 2024, and at times prior thereto, employees were exposed to fire hazards when using a spray area without mechanical ventilation to reduce flammable vapor mists.
Recent events (1)
  • — Z (S) $0

1910.107 E02

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 30, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.107(e)(2):The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 degrees F (93 degrees C) kept in the vicinity of spraying operations were not a minimum required for operations or they exceeded a supply for one day or one shift:  Spray area: On or about January 19, 2024, and at times prior thereto, employees were exposed to fire hazards when more of a supply for one day's worth of paint that was flammable was stored in the vicinity of spraying operations.
Recent events (1)
  • — Z (S) $0

1910.159 C02

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 30, 2024
Abate by
Jun 3, 2024
Penalty
Initial $2,765 · Current $2,765
29 CFR  1910.159(c)(2):The employer did not properly maintain the installed automatic sprinkler system. The employer did not ensure that a main drain flow test is performed on each system annually. The inspector's test valve shall be opened at least every two years to assure that the sprinkler system operates properly.  Bay areas: On or about January 19, 2024, and at times prior thereto,  employees were exposed to fire hazards when the sprinkler system was not maintained annually.
Recent events (1)
  • — Z (S) $2765

1910.213 D01

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 30, 2024
Abate by
Jun 3, 2024
Penalty
Initial $4,148 · Current $4,148
29 CFR  1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  Assembly Bay: On or about January 19, 2024, and at times prior thereto, employees were exposed to amputation hazards from an unguarded blade from the SawStop stationary cabinet saw.
Recent events (1)
  • — Z (S) $4148

1910.305 B01 II

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 30, 2024
Abate by
Jun 3, 2024
Penalty
Initial $2,765 · Current $2,765
29 CFR  1910.305(b)(1)(ii):Unused openings in boxes, cabinets, or fittings were not effectively closed:  Near the spray area: On or about January 19, 2024, and at times prior thereto, employees were exposed to electrical hazards due to a knockout missing from the electrical panel.
Recent events (1)
  • — Z (S) $2765

1910.305 G01 IV B

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 30, 2024
Penalty
Initial $2,765 · Current $2,765
29 CFR  1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors:  Cabinet Assembly Bay: On or about January 19, 2024, and at times prior thereto, employees were exposed to an electrical hazard from a flexible cord running through walls and ceilings.
Recent events (1)
  • — Z (S) $2765

1910.334 A02 I

Serious Gravity 1 3 instances 5 exposed
Issued
Apr 30, 2024
Penalty
Initial $2,074 · Current $2,074
29 CFR  1910.334(a)(2)(i):Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  1) Cabinet Assembly Bay: On or about January 19, 2024, and at times prior thereto, employees were exposed to a fire hazard when using Delta Router / Shaper that had exposed wiring covered with blue tape.  2-3) Cabinet Assembly Bay: On or about January 19, 2024, and at times prior thereto, employees were exposed to a fire hazard when an orange extension cord was sliced and taped up with black tape.
Recent events (1)
  • — Z (S) $2074

1910.1200 E01

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 30, 2024
Abate by
Jun 3, 2024
Penalty
Initial $2,074 · Current $2,074
29 CFR  1910.1200(e)(1):Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):   Spray area bay: On or about January 19, 2024, and at times prior thereto, employees were exposed to chemical hazards while not provided with a hazard communication program which includes information and training, safety data sheets, and proper labeling of secondary containers for such as but not limited to paint thinners, and wood paint.
Recent events (1)
  • — Z (S) $2074

1910.132 D01

Other-than-serious 1 instance 5 exposed
Issued
Apr 30, 2024
Abate by
Jun 3, 2024
Penalty
Initial $388 · Current $388
29 CFR  1910.132(d)(1):The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):   On or about January 19, 2024, and at times prior thereto,   employees were exposed to chemical splashes and chemical contact when there was not a workplace hazard assessment for personal protective equipment.
Recent events (1)
  • — Z (O) $388

1910.157 E03

Other-than-serious 1 instance 5 exposed
Issued
Apr 30, 2024
Abate by
Jun 3, 2024
Penalty
Initial $388 · Current $388
29 CFR  1910.157(e)(3):Portable fire extinguishers were not subjected to an annual maintenance check:  Bay areas: On or about January 19, 2024, and at times prior thereto,  employees were exposed to fire hazards when spraying with flammable liquids and the employer did not conduct annual maintenance inspections of the portable fire extinguishers.
Recent events (1)
  • — Z (O) $388

View Alexander Grey Custom Cabinets's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347219941.