ARLINGTON HEIGHTS, IL —
OSHA Inspection: RMA CUSTOM CARPENTRY, CO.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RMA CUSTOM CARPENTRY, CO. in 1245 S. ARLINGTON HEIGHTS ROAD, ARLINGTON HEIGHTS, IL 60005 (NAICS 238130). OSHA activity number 347225302.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RMA CUSTOM CARPENTRY, CO.
- Site address
- 1245 S. ARLINGTON HEIGHTS ROAD
- City
- ARLINGTON HEIGHTS
- State
- IL
- ZIP
- 60005
- Mailing
- 321 PARK DRIVE, JOLIET, IL 60436
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- Mar 7, 2024
- Penalty
- Initial $2,765 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: a) On or about January 22, 2024, employees were exposed to eye injury while operating pneumatic nail guns and electric saws without the benefit of eye protection. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $2500
- — Z (S) $2765
1926.404 B01 II
- Issued
- Mar 7, 2024
- Penalty
- Initial $3,457 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) On or about January 22, 2024, employees were provided with electrical tools and equipment connected by cord and plug to a Honda portable generator, having 5000 watts of start-up power, without the use of ground fault circuit interrupters or an assured equipment grounding conductor program. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $3457
1926.501 B13
- Issued
- Mar 7, 2024
- Penalty
- Initial $4,839 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) On or about January 22, 2024, employees were exposed to the hazard of falling approximately 11 feet while engaged in carpentry work working from elevated surfaces without fall protection. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $3000
- — Z (S) $4839
1926.1053 B01
- Issued
- Mar 7, 2024
- Penalty
- Initial $4,839 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about January 22, 2024, employees were exposed to the hazard of falling approximately 11 feet where a portable extension ladder did not extend at least 3 feet above the roof landing surface. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $3000
- — Z (S) $4839
More inspections at RMA Custom Carpentry, CO.
View RMA Custom Carpentry, CO.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347225302.