Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNIVERSAL MARBLE IMPORT CORPORATION

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of UNIVERSAL MARBLE IMPORT CORPORATION in 9810 MCCULLOUGH AVENUE, SAN ANTONIO, TX 78216 (NAICS 327991). OSHA activity number 347227035.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Universal Marble Import Corporation — free Get an email when a new federal OSHA severe-injury report for Universal Marble Import Corporation is published. One employer, no account, unsubscribe in one click.
Site address
9810 MCCULLOUGH AVENUE
City
SAN ANTONIO
State
TX
ZIP
78216
Mailing
9810 MCCULLOUGH AVENUE, SAN ANTONIO, TX 78216
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327991
Employees
4
Ownership type
A

7 citations on file for this inspection.

1910.157 E03

Serious Gravity 1 2 instances 4 exposed
Issued
Apr 30, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  Shop areas: On or about January 23, 2024, and at times prior thereto,  employees were exposed to fire hazards when using flammable liquids and the employer did not conduct annual maintenance inspections of the portable fire extinguishers.
Recent events (1)
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 30, 2024
Abate by
Jun 3, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(2)(i):Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  Shop area: On or about January 23, 2024, and at times prior thereto,  employees were exposed to fire hazards when having an electrical outlet not covered with a faceplate.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV B

Serious Gravity 5 2 instances 4 exposed
Issued
Apr 30, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(B):Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used: Where run through holes in walls, ceilings, or floors.  Shop area: On or about January 23, 2024, and at times prior thereto,  employees were exposed to fire hazards when using portable machinery that was plugged in on flexible electrical cords that were run through ceilings throughout the facility.
Recent events (1)
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 30, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(2)(i):Portable cord and plug-connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects.  Shop area: On or about January 23, 2024, and at times prior thereto,  employees were exposed to fire hazards when using flexible electrical cords that were damaged, bent, or frayed and taped up with electrical tape.
Recent events (1)
  • — Z (S) $0

1910.1053 F02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 30, 2024
Abate by
Jun 3, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.1053(f)(2)(i):The employer did not establish and implement a written exposure control plan:  Shop Area: On or about January 23, 2024, and at times prior thereto,  employees are exposed to respirable silica when cutting or grinding granite or marble, and the employer had not established a written exposure control plan.
Recent events (1)
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 30, 2024
Abate by
Jun 3, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(e)(1):The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  Shop area: On or about January 23, 2024, and at times prior thereto,  employees were exposed to chemical hazards such as but not limited to flammable liquids, and respirable silica quartz while not provided with a hazard communication program which includes information and training, safety data sheets, and proper labeling of secondary containers.
Recent events (1)
  • — Z (S) $0

1910.134 K06

Other-than-serious 1 instance 4 exposed
Issued
Apr 30, 2024
Abate by
Jun 3, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.134(k)(6):The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer.  Shop area: On or about January 23, 2024, and at times prior thereto, employees were exposed to respiratory hazards by failing to provide employees who voluntarily wear N95 dust masks with basic advisory information on respirators as presented in Appendix D of 29 CFR 1910.134.