TOMAH, WI —
OSHA Inspection: INTERCOOL USA LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of INTERCOOL USA LLC in 525 INDUSTRIAL AVE, TOMAH, WI 54660 (NAICS 238220). OSHA activity number 347230146.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INTERCOOL USA LLC
- Site address
- 525 INDUSTRIAL AVE
- City
- TOMAH
- State
- WI
- ZIP
- 54660
- Mailing
- 1313 VALWOOD PARKWAY, CARROLLTON, TX 75006
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 11
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B01
- Issued
- Mar 25, 2024
- Abate by
- Apr 19, 2024
- Penalty
- Initial $8,816 · Current $8,816
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. On or about January 24, 2024, the employer did not ensure that all employees were protected from fall hazards greater than 25 feet by the use of guardrail systems, safety net systems, or personal fall arrest systems.
Recent events (2)
- — I (S) $8816
- — Z (S) $8816
1926.503 A02 II
- Issued
- Mar 25, 2024
- Abate by
- Apr 19, 2024
- Penalty
- Initial $8,816 · Current $0 Reduced
General-duty citation text
1926.503(a)(2)(ii) The correct procedures for erecting, maintaining, disassembling, and inspecting the fall protection systems to be used; 29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person: On or about January 24, 2024, employees approaching the roof edge were not protected from falls due to utilizing Trirex Raptor Fall Protection Cart(s) as part of a complete personal fall arrest system in deviation of the manufacturer's specifications on a snow/ice substrate.
Recent events (2)
- — I (S) $0
- — Z (S) $8816
1926.502 F02 I
- Issued
- Mar 25, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(f)(2)(i): The rope, wire, or chain was not flagged at no more than 6-foot intervals with high-visibility material: On or about January 24, 2024, the wire on the Warehouse Roof used as part of a warning line system was not flagged at intervals of no more than 6-foot with high-visibility material.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Intercool USA LLC
View Intercool USA LLC's full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347230146.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.