DE SMET, SD —
OSHA Inspection: ULTIMED, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ULTIMED, INC. in 710 4TH STREET SOUTHEAST, DE SMET, SD 57231 (NAICS 339112). OSHA activity number 347230310.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ULTIMED, INC.
- Site address
- 710 4TH STREET SOUTHEAST
- City
- DE SMET
- State
- SD
- ZIP
- 57231
- Mailing
- 350 HIGHWAY 7 SUITE 100, EXCELSIOR, MN 55331
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339112
- Employees
- 34
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.147 C04 II
- Issued
- Apr 23, 2024
- Abate by
- Jun 20, 2024
- Penalty
- Initial $8,067 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance: (a)UltiMed, Inc. at 4th Street Southeast, De Smet, SD 57231: On or about and at times prior to January 24, 2024, the employer did not ensure rules and techniques involving specific energy control procedures to control hazardous energy were implemented or enforced which resulted in exposure to hazards associated with the PNUG Machine, Asset Number: SA03-300, Serial Number: 10605-A1 . This condition exposed employees to crushing, amputation, shock, and air embolisms.
Recent events (2)
- — I (S) $5000
- — Z (S) $8067
1910.147 C06 I
- Issued
- Apr 23, 2024
- Abate by
- Jun 20, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a)UltiMed, Inc. at 4th Street Southeast, De Smet, SD 57231: On or about and at times prior to January 24, 2024, the employer did not ensure a periodic inspection was conducted at least annually to ensure that its lockout/tagout program was being followed and any deviations or inadequacies were identified. This condition exposed employees to amputation, crushing and shock hazards associated with an improperly locked out equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D02
- Issued
- Apr 23, 2024
- Abate by
- Jun 20, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the employer's energy control procedures required by this standard: (a)UltiMed, Inc. at 4th Street Southeast, De Smet, SD 57231: On or about and at times prior to January 24, 2024, the employer did not ensure specific energy control procedures to deenergize the PNUG Machine, Asset Number: SA03-300, Serial Number: 10605-A1 were utilized prior to operators entering the machine area/danger zone. This condition exposed employees to crushing, amputation, shock, and air embolisms while accessing the equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Apr 23, 2024
- Abate by
- Jun 20, 2024
- Penalty
- Initial $11,292 · Current $9,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a)UltiMed, Inc. at 4th Street Southeast, De Smet, SD 57231: On or about and at times prior to March 18, 2024, the employer did not ensure the Pen Needle Hub Assembly Machine - Automatic Korea, Model Number: AK-PNA, Serial Number: AK-PNA-S20140825 was properly guarded to prevent employees from having any part of their body in the danger zones during machine operations. This condition exposed employees to caught in, crushing, and amputation hazards.
Recent events (2)
- — I (S) $9000
- — Z (S) $11292
1910.215 A04
- Issued
- Apr 23, 2024
- Abate by
- May 23, 2024
- Penalty
- Initial $4,839 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rests on grinding machinery were not adjusted closely to the wheel with a maximum opening of 1/8 inch: (a)UltiMed, Inc. at 4th Street Southeast, De Smet, SD 57231: On or about and at times prior to January 24, 2024, the employer did not ensure that the work rest on the Pro-Tech 6-inch Bench Grinder, Model # 8103, Serial Number 2030002928 within the Maintenance Room was adjusted to allow a max opening of 1/8 inch. This condition exposed employees to struck by hazards associated with grinding wheel breakage.
Recent events (2)
- — I (S) $2800
- — Z (S) $4839
1910.215 B09
- Issued
- Apr 23, 2024
- Abate by
- May 23, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch: (a)UltiMed, Inc. at 4th Street Southeast, De Smet, SD 57231: On or about and at times prior to January 24, 2024, the employer did not ensure that the adjustable tongue on the Pro-Tech 6-inch Bench Grinder, Model # 8103, Serial Number 2030002928 being utilized within the Maintenance Room was adjusted to a distance not to exceed one-fourth inch. This condition exposed employees to struck-by hazards associated with grinding wheel breakage.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 F03
- Issued
- Apr 23, 2024
- Abate by
- May 23, 2024
- Penalty
- Initial $4,839 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: (a)UltiMed, Inc. at 4th Street Southeast, De Smet, SD 57231: On or about and at times prior to January 24, 2024, the employer did not ensure the chain and sprocket on the PNUG Machine, Asset Number: SA03-300, Serial Number: 10605-A1 was enclosed. This condition exposed employee to caught-in and amputation hazards associated with the unguarded drive chain and sprocket.
Recent events (2)
- — I (S) $2800
- — Z (S) $4839
1910.219 H01
- Issued
- Apr 23, 2024
- Abate by
- May 23, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(h)(1): Projecting keys, setscrews, or other projections in revolving parts were not removed, made flush, or guarded by metal covers: (a)UltiMed, Inc. at 4th Street Southeast, De Smet, SD 57231: On or about and at times prior to January 24, 2024, the employer did not ensure spinning drive mechanisms with a projecting setscrew head on the PNUG Machine, Asset Number: SA03-300, Serial Number: 10605-A1 was effectively guarded. This condition exposed employees to caught-in hazards associated with the unguarded setscrew on the drive mechanism.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B07 I
- Issued
- Apr 23, 2024
- Abate by
- May 23, 2024
- Penalty
- Initial $4,839 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: (a)UltiMed, Inc. at 4th Street Southeast, De Smet, SD 57231: On or about and at times prior to January 24, 2024, the employer did not ensure that electrical equipment was effectively closed, in that employees were exposed to live electrical circuits associated with two missing knockouts on the 240-volt 3 phase power panel on the north wall in the Receiving Warehouse. This condition exposed employees to shock and electrocution as well as fire hazards associated with exposed wiring on the electrical box. (b)UltiMed, Inc. at 4th Street Southeast, De Smet, SD 57231: On or about and at times prior to January 24, 2024, the employer did not ensure that electrical equipment was effectively closed, in that employees were exposed to live electrical circuits associated with a missing electrical breaker in a 240-volt 3 phase power panel on the west wall of the Third Bay area. This condition exposed employees to shock and electrocution as well as fire hazards associated with exposed wiring on the electrical box.
Recent events (2)
- — I (O) $2800
- — Z (S) $4839
1910.37 A03
- Issued
- Apr 23, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not kept free and unobstructed: (a)UltiMed, Inc. at 4th Street Southeast, De Smet, SD 57231: On or about and at times prior to January 24, 2024, the employer did not ensure that employees exit routes and means of emergency egress were kept free and unobstructed in that snow and ice blocked the north emergency exit door in the Receiving Warehouse area. This condition exposed employees to emergency egress hazards. (b)UltiMed, Inc. at 4th Street Southeast, De Smet, SD 57231: On or about and at times prior to January 24, 2024, the employer did not ensure that employees exit routes and means of emergency egress were kept free and unobstructed in that snow and ice blocked the south emergency exit door in the Receiving Warehouse area. This condition exposed employees to emergency egress hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 Q07
- Issued
- Apr 23, 2024
- Abate by
- May 23, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined at least daily before being placed in service: (a)UltiMed, Inc. at 4th Street Southeast, De Smet, SD 57231: On or about and at times prior to January 24, 2024, the employer did not ensure that a New Tec, Inc. Pallet Jack powered industrial truck, Asset Number: SA05-107, was being examined at least daily prior to use. This condition exposed employees to struck-by hazards associated with inoperable powered industrial trucks. (b)UltiMed, Inc. at 4th Street Southeast, De Smet, SD 57231: On or about and at times prior to January 24, 2024, the employer did not ensure that a Toyota powered industrial truck, Model Number: 7FBEU15, Serial Number: 14709 was being examined at least daily prior to use. This condition exposed employees to struck-by hazards associated with inoperable powered industrial trucks. (c)UltiMed, Inc. at 4th Street Southeast, De Smet, SD 57231: On or about and at times prior to January 24, 2024, the employer did not ensure that a Toyota powered industrial truck, Model Number: 7BRU23, Serial Number: 7BRU23-34265 was being examined at least daily prior to use. This condition exposed employees to struck-by hazards associated with inoperable powered industrial trucks.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 339112)
More inspections in SD
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347230310.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.