NEW CASTLE, PA —
OSHA Inspection: CUSTOM VALVE REPAIR, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CUSTOM VALVE REPAIR, LLC in 3589 HARLANSBURG ROAD, NEW CASTLE, PA 16101 (NAICS 811219). OSHA activity number 347232779.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CUSTOM VALVE REPAIR, LLC
- Site address
- 3589 HARLANSBURG ROAD
- City
- NEW CASTLE
- State
- PA
- ZIP
- 16101
- Mailing
- 3589 HARLANSBURG ROAD, NEW CASTLE, PA 16101
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811219
- Employees
- 30
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- May 7, 2024
- Abate by
- Jun 3, 2024
- Penalty
- Initial $8,228 · Current $3,900 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to electrical and struck-by hazards associated with the use of the Reading 5-ton hoist (serial #13304). a.) Custom Valve Repair, LLC 3589 Harlansburg Road New Castle, PA 16101, on or about 01/25/2024, and times prior thereto: The emergency stop button on the Reading 5-ton hoist serial #13304 pendant was missing. Hoist pendant was used to lift equipment including but not limited to, large control valves. b.) Custom Valve Repair, LLC 3589 Harlansburg Road New Castle, PA 16101, on or about 01/25/2024, and times prior thereto: Periodic inspections are not performed or documented on the hoists. Hoists include, but is not limited to, Reading 5-ton hoist (Serial number 13304), and Reading 5-ton hoist (Serial number 13305).
Recent events (2)
- — I (S) $3900
- — Z (S) $8228
1910.179 J02
- Issued
- May 7, 2024
- Abate by
- Jun 3, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(2): Overhead cranes were not inspected on frequent intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections: a.) Custom Valve Repair, LLC 3589 Harlansburg Road New Castle, PA 16101, on or about 01/25/2024, and times prior thereto: the company had not performed frequent inspections on the cranes. Cranes include, but is not limited to, Reading 15-ton crane (Serial number 18495).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 J03
- Issued
- May 7, 2024
- Abate by
- Jun 3, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(3): Complete inspections of the crane was not being performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section: a.) Custom Valve Repair, LLC 3589 Harlansburg Road New Castle, PA 16101, on or about 01/25/2024, and times prior thereto: the company had not performed periodic inspections on the cranes. Cranes include, but is not limited to, Reading 15-ton crane (Serial number 18495).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 G01 V
- Issued
- May 7, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not clearly marked for identification of functions: a.) Custom Valve Repair, LLC 3589 Harlansburg Road New Castle, PA 16101, on or about 01/25/2024, and times prior thereto: The Reading 15-ton overhead bridge crane serial #18495 pendant was missing directional labels on two push-buttons. Crane remote was used to lift equipment including but not limited to large control valves.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L04 III
- Issued
- May 7, 2024
- Abate by
- Jun 3, 2024
- Penalty
- Initial $5,485 · Current $3,900 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii):An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a.) Custom Valve Repair, LLC 3589 Harlansburg Road New Castle, PA 16101, on or about 01/25/2024, and times prior thereto: employees operated powered industrial trucks including but not limited to, a Komatsu FG25T-16 forklift (serial number A410799) and had not completed an operator evaluation every 3 years.
Recent events (2)
- — I (S) $3900
- — Z (S) $5485
1910.1200 F06 II
- Issued
- May 7, 2024
- Abate by
- Jun 3, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical a.) Custom Valve Repair, LLC 3589 Harlansburg Road New Castle, PA 16101, on or about 01/25/2024, and times prior thereto: Three chemical containers located in the flammable liquid storage cabinet outside the break room were not labeled correctly in that the containers with a white cap weren't labeled and contained Penncut 150 oil. The company's squeeze bottle cap color code system states that Penncut 150 oil should be in a green cap container and white cap squeeze bottles need a hazard warning label.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Custom Valve Repair, LLC
View Custom Valve Repair, LLC's full OSHA safety record →
More inspections in this industry (NAICS 811219)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347232779.