Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WALASHEK INDUSTRIAL & MARINE, INC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of WALASHEK INDUSTRIAL & MARINE, INC in BUILDING 31C2T (TEMP FABRIC SHELTER) ACU 5: PO BOX 55161, OCEANSIDE, CA 92049 (NAICS 336611). OSHA activity number 347235962.

Watch Walashek Industrial & Marine, INC — free Get an email when a new federal OSHA severe-injury report for Walashek Industrial & Marine, INC is published. One employer, no account, unsubscribe in one click.
Site address
BUILDING 31C2T (TEMP FABRIC SHELTER) ACU 5: PO BOX 55161
City
OCEANSIDE
State
CA
ZIP
92049
Mailing
1428 MCKINLEY AVENUE, NATIONAL CITY, CA 91950
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
64
Ownership type
A

10 citations on file for this inspection.

1910.134 C03

Other-than-serious Gravity 1 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $6222.00 · Current $0.00 Reduced
29 CFR  1910.134(c)(3): The employer did not designate a program administrator who was qualified by appropriate training or experience to administer or oversee the respiratory protection program and to conduct the required evaluations of program effectiveness:  Building 31C2T: Onboard LCAC 90, LCAC 62, and LCAC 81: On and/or before March 14, 2024, employees conducted the following operations:  a. Confined Space: Fuel tank cleaning b. Enclosed Space: Tungsten Inert Gas (TIG)/Metal Inert Gas (MIG) welding  Employees were required to wear 3M half mask tight-fitting respirators with cartridges. The employer did not designate a program administrator who was qualified by appropriate training or experience to administer the respiratory program and conduct required evaluations of program effectiveness.  This condition potentially exposed employees to central nervous system depression, bronchospams, asthma, pneumonia, mental confusion, metal fume fever, and myocardium sensitization which may result in ventricular fibrillation.
Recent events (3)
  • — R (O) $0
  • — C (S) $6222
  • — Z (S) $6222

1910.134 D01 III

Serious Gravity 1 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  Building 31C2T: Onboard LCAC 90, LCAC 62, and LCAC 81: On and/or before March 14, 2024, employees conducted the following operations:  a. Confined Space: Fuel tank cleaning b. Enclosed Space: Tungsten Inert Gas (TIG)/Metal Inert Gas (MIG) welding  Employees were required to wear 3M half mask tight-fitting respirators with cartridges. The employer did not identify and evaluate the respiratory hazard(s) in the workplace, including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form.  This condition potentially exposed employees to central nervous system depression, bronchospams, asthma, pneumonia, metal fume fever, mental confusion, and myocardium sensitization which may result in ventricular fibrillation.
Recent events (3)
  • — R (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 D01 IV

Other-than-serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $6222.00 · Current $6222.00
29 CFR  1910.134(d)(1)(iv): The employer did not select respirators from a sufficient number of respirator models and sizes to ensure the respirators used in the worksite were acceptable to and correctly fit the users:  Building 31C2T: Onboard LCAC 81: On and/or before March 14, 2024, fuel tank cleaning occurred inside confined spaces. The employees were required to wear 3M half mask tight-fitting respirators with 3M 6001 organic vapor cartridges. The employer did not have a sufficient number of respirator models and sizes available to ensure correct fit for all users. This condition potentially exposed employees to fuel vapors which can result in central nervous system depression, mental confusion, and myocardium sensitization which may result in ventricular fibrillation.
Recent events (3)
  • — R (O) $6222
  • — C (S) $6222
  • — Z (S) $6222

1910.134 F02

Other-than-serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:  Building 31C2T: Onboard LCAC 81: On and/or before March 14, 2024, fuel tank cleaning occurred, and employees were required to wear 3M half mask tight-fitting respirators with 3M 6001 grey (organic vapor) cartridges while working inside confined spaces.  The employer did not ensure annual respirator fit tests were completed prior to initiating the fuel cleaning operations. This condition potentially exposed employees to fuel vapors which can result in central nervous system depression, mental confusion, and myocardium sensitization which may result in ventricular fibrillation.
Recent events (3)
  • — R (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 G01 I A

Deleted Serious Gravity 1 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $6222.00 · Current $0.00 Reduced
29 CFR  1910.134(g)(1)(i)(A):  Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:  Building 31C2T: Onboard LCAC 90, LCAC 62, and LCAC 81: On and/or before March 14, 2024, employees conducted the following operations:  a. Confined Space: Fuel tank cleaning b. Enclosed Space: Tungsten Inert Gas (TIG)/Metal Inert Gas (MIG) welding  Employees were required to wear 3M half mask tight-fitting respirators with cartridges. The employer did not ensure employees were free of facial hair while wearing half mask tight-fitting respirators. This condition potentially exposed employees to central nervous system depression, bronchospams, asthma, pneumonia, metal fume fever, mental confusion, and myocardium sensitization which may result in ventricular fibrillation.
Recent events (3)
  • — R (S) $0
  • — C (S) $6222
  • — Z (S) $6222

1910.134 K01 II

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $6222.00
29 CFR  1910.134(k)(1)(ii): The employer did not ensure that each employee could demonstrate knowledge of the limitations and capabilities of the respirator:   Building 31C2T: Onboard LCAC 81: On and/or before March 14, 2024, fuel tank cleaning occurred, and employees were required to wear 3M half mask tight-fitting respirators with 3M 6001 grey (organic vapor) and/or 3M 6003 yellow (organic vapor/acid gas) cartridges while working inside a confined space.  The employer did not provide effective training for employees to demonstrate knowledge of the respirator's limitations and capabilities for the confined space environment.  This condition potentially exposed employees to fuel vapors which can result in central nervous system depression, mental confusion, and myocardium sensitization which may result in ventricular fibrillation.  The employer did not ensure that employees were free of facial hair while wearing half mask tight-fitting respirators. This condition potentially exposed employees to central nervous system depression, bronchospasms, asthma, pneumonia, metal fume fever, mental confusion, and myocardium sensitization which may result in ventricular fibrillation.
Recent events (3)
  • — R (S) $6222
  • — C (S) $0
  • — Z (S) $0

1915.56 E

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $6222.00 · Current $6222.00
29 CFR  1915.56(e): Arc welding and cutting operations were not shielded by noncombustible or flameproof screens to protect employees in the vicinity from the direct rays of the arc.  Building 31C2T: Onboard LCAC 90 and LCAC 62: On and/or before January 25, 2024, employees conducted Tungsten Inert Gas (TIG)/Metal Inert Gas (MIG) welding on aluminum and stainless steel in enclosed spaces with two open sides where other employees worked, staged materials, and frequently walked on/off the vessel.  The employer had not shielded the work from employees working in the vicinity of the welding operations which potentially exposed employees to UV radiation hazards.
Recent events (3)
  • — R (S) $6222
  • — C (S) $6222
  • — Z (S) $6222

1915.157 A

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6222.00 · Current $0.00 Reduced
29 CFR  1915.157(a): The employer did not ensure that employees used appropriate hand protection or protective clothing when exposed to hazards such as skin absorption of harmful substances, severe cuts, lacerations, abrasions, punctures, chemical burns, thermal burns, harmful temperature extremes, and sharp objects.  Building 31C2T: Onboard LCAC 90 and LCAC 62: On and/or before January 25, 2024, employees conducted Tungsten Inert Gas (TIG)/Metal Inert Gas (MIG) welding on aluminum and stainless steel inside enclosed spaces where employees wore (non-fire retardant) personal clothing with no welding leathers or welding apron as protection from metal shards, molten metals, sparks/flying particulates, and residual heat. The employer had not ensured protective clothing or covering was worn which potentially exposed employees to dermal burns.
Recent events (3)
  • — R (S) $0
  • — C (S) $6222
  • — Z (S) $6222

1915.153 A01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1165.00 · Current $1165.00
29 CFR  1915.153(a)(1): The employer did not ensure that employees used appropriate eye or face protection where there were exposures to eye or face hazards caused by flying particles, molten metal, liquid chemicals, acid, caustic liquids, gases, vapors, or potentially injurious light radiation.  Building 31C2T: Onboard LCAC 62: On and/or before January 25, 2024, employees conducted Tungsten Inert Gas (TIG)/Metal Inert Gas (MIG) welding on aluminum and stainless steel on vessel decking. Employees wore Black Stallion single layer knit headcovers only and did not consistently wear them correctly as face protection from metal shards, slag, and residual heat. Employees also wore (non fire-retardant) personal clothing with no welding leathers or apron as protection from metal shards molten metals, sparks/flying particulates, and residual heat. The employer had not ensured appropriate face and body protection was properly donned, which potentially exposed employees
Recent events (3)
  • — R (O) $1165
  • — C (O) $1165
  • — Z (O) $1165

1910.95 D03 I

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1165.00 · Current $1165.00
29 CFR  1910.95(d)(3)(i): The employer did not perform repeat employee exposure monitoring when additional employees may be exposed at or above the action level:  Building 31C2T: Onboard LCAC 62 and LCAC 90: On and/or before January 25, 2024, employees conducted grinding, cutting, and welding operations onboard.  The employer did not perform employee exposure monitoring for noise during assigned tasks and when employees, including temporary hires, may be exposed at or above the action level which potentially exposed employees to hearing loss.
Recent events (3)
  • — R (O) $1165
  • — C (O) $1165
  • — Z (O) $1165

View WALASHEK INDUSTRIAL & MARINE, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347235962.