MONTGOMERY, AL —
OSHA Inspection: JAY R. SMITH MFG. CO.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JAY R. SMITH MFG. CO. in 2781 GUNTER PARK DR E, MONTGOMERY, AL 36109 (NAICS 332913). OSHA activity number 347236549.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JAY R. SMITH MFG. CO.
- Site address
- 2781 GUNTER PARK DR E
- City
- MONTGOMERY
- State
- AL
- ZIP
- 36109
- Mailing
- 2781 GUNTER PARK DR E, MONTGOMERY, AL 36109
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332913
- Employees
- 260
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Feb 28, 2024
- Abate by
- Mar 13, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Machine shop; On or about January 24, 2024 and times prior the employer failed to ensure guarding was provided to protect the operator of the Kaufman K-4 304 drilling machine from the point of operation.
Recent events (1)
- — Z (O) $0
1910.303 G01 II
- Issued
- Feb 28, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii):The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) Fabrication Shop, Laser Room; On or about January 24, 2024 and times prior the employer failed to ensure the working space around electrical panels were not used for storage of materials and equipment.
Recent events (1)
- — Z (O) $0
1910.132 D02
- Issued
- Feb 28, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2):The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: a) Fabrication Shop; On or about January 24, 2024 and times prior the employer failed to verify that the required workplace hazard assessment had been performed through a written certification that identified the workplace evaluated, the person certifying that the evaluation had been performed, the date(s) of the hazard assessment, and which identified the document as a certification of hazard assessment for tasks such as, but not limited to, operating press brakes.
Recent events (1)
- — Z (O) $0
More inspections at JAY R. Smith MFG. CO.