PAGO PAGO, AS —
OSHA Inspection: VAILU'U & SONS CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VAILU'U & SONS CONSTRUCTION in M7PH+37W NUUULI, PAGO PAGO, AS 96799 (NAICS 236220). OSHA activity number 347237695.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VAILU'U & SONS CONSTRUCTION
- Site address
- M7PH+37W NUUULI
- City
- PAGO PAGO
- State
- AS
- ZIP
- 96799
- Mailing
- VAILU'U & SONS CONSTRUCTION P. O. BOX 838, PAGO PAGO, AS 96799
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 21
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B01
- Issued
- Mar 26, 2024
- Abate by
- Apr 5, 2024
- Penalty
- Initial $4,610 · Current $4,610
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Tautai parking lot project: An employee was passing tools to the employees below while standing and squatting on a retaining wall over nine feet high. The employee was exposed to fall hazards.
Recent events (1)
- — Z (S) $4610
1926.1052 C01 II
- Issued
- Mar 26, 2024
- Abate by
- Apr 5, 2024
- Penalty
- Initial $2,765 · Current $2,765
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: Left side of retaining wall, closer to Tautai building: The stairs used to access the upper area where the tools and materials were being kept were not equipped with a stair rail along the unprotected edge. Employees were exposed to fall hazards.
Recent events (1)
- — Z (S) $2765
1926.403 B02
- Issued
- Mar 26, 2024
- Abate by
- Apr 5, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: Retaining wall: Two extension cords were connected-in-series (daisy chained) to provide power to the power tools used to build the form for the retaining wall. Employees were exposed electrical hazards.
Recent events (1)
- — Z (O) $0
More inspections at Vailu'U & Sons Construction
View Vailu'U & Sons Construction's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in AS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347237695.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.