Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INDUSTRIAL GASES INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of INDUSTRIAL GASES INC. in TAFUNA, PAGO PAGO, AS 96799 (NAICS 221210). OSHA activity number 347238248.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Industrial Gases INC. — free Get an email when a new federal OSHA severe-injury report for Industrial Gases INC. is published. One employer, no account, unsubscribe in one click.
Site address
TAFUNA
City
PAGO PAGO
State
AS
ZIP
96799
Mailing
P O BOX 5664, PAGO PAGO, AS 96799
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221210
Employees
35
Ownership type
A

9 citations on file for this inspection.

1926.95 A

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 22, 2024
Abate by
May 2, 2024
Penalty
Initial $4,839 · Current $2,903 Reduced
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and/or maintained in a sanitary and reliable condition:  Living room: Employees working with the Weber ceramic tile adhesive mixture to lay tiles did not have hand protection. Employees were exposed to chemical hazards..
Recent events (2)
  • — I (S) $2903.4
  • — Z (S) $4839

1926.102 A01

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 22, 2024
Abate by
May 2, 2024
Penalty
Initial $4,839 · Current $0 Reduced
29 CFR 1926.102(a)(1): Employees did not use eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:  Living Room: Employee using the electric drill to mix the Weber set Adhesive for the floor tiles without safety glasses were exposed to chemical eye burn hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4839

1926.403 B02

Serious Gravity 1 3 instances 3 exposed
Issued
Apr 22, 2024
Abate by
May 2, 2024
Penalty
Initial $4,839 · Current $2,903 Reduced
29 CFR 1926.403(b)(2): Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.  a Living Room: Three receptacle outlet boxes intended to be mounted in the walls were suspended from the ceiling and used to provide power for tools and equipment on the jobsite. Employees were exposed to electrical hazards.   b. Living room: A blue receptacle outlet box intended to be mounted on a wall was hung from the ceiling and used to provide power for a fan used for ventilation. Employees were exposed to electrical hazards.    c. Lanai: A blue receptacle outlet box intended to be mounted on a wall was laid on the floor and used to provide power to the chop saw that was used to cut tiles. Employees were exposed to electrical hazards.
Recent events (2)
  • — I (S) $2903.4
  • — Z (S) $4839

1926.405 G02 III

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 22, 2024
Abate by
May 2, 2024
Penalty
Initial $4,839 · Current $2,903 Reduced
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used only in continuous lengths without splice or tap:  Living Room: A spliced extension cord was used to power the drill used to mix the Weber ceramic adhesive for the tiles. Employees were exposed to electrical hazards.
Recent events (2)
  • — I (S) $2903.4
  • — Z (S) $4839

1926.405 J01

Serious Gravity 1 2 instances 3 exposed
Issued
Apr 22, 2024
Abate by
May 2, 2024
Penalty
Initial $4,839 · Current $2,903 Reduced
29 CFR 1926.405(j)(1):29 CFR 1926.405(j)(1):  Fixtures, lampholders, lamps, rosettes, and receptacles had live parts exposed to employee contact.  a. Living Room: Live wiring from receptacles were not mounted in gang boxes, exposed employees to electrical hazards.  b. Living room: Exposed live wiring entering a blue outlet receptacle used to power a fan exposed employees to electrical hazards.
Recent events (2)
  • — I (S) $2903.4
  • — Z (S) $4839

1910.1200 E01

Other-than-serious 1 instance 3 exposed
Issued
Apr 22, 2024
Abate by
May 16, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement and maintain at the workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g) and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met:  A written hazard communication program was not developed for employees required to work with hazardous chemicals such as Weber Ceramic Tile Adhesive for Wall and Floor and Henry 440 adhesive. Employees were exposed to chemical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G08

Other-than-serious 1 instance 3 exposed
Issued
Apr 22, 2024
Abate by
May 2, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required safety data sheets for each hazardous chemical in the workplace:  Copies of the safety data sheets for the Weberset Ceramic Tile Adhesive for Walls and Floor were not maintained onsite.  Employees were exposed to chemical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.405 B02

Other-than-serious 2 instances 3 exposed
Issued
Apr 22, 2024
Abate by
May 2, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.405(b)(2): All pull boxes, junction boxes, or fittings were not provided with covers:  a. Living room: An extension cord used to power a vacuum was plugged into an outlet with no cover exposing employees to electrical hazards.   b. living Room: An extension cord used to power a drill and a grinder was plugged into an outlet with no cover. Employees were exposed to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.405 G02 IV

Other-than-serious 2 instances 3 exposed
Issued
Apr 22, 2024
Abate by
May 2, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): The employer shall ensure that flexible cords are connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.  a. Living room: The outer insulation to the extension cord used to power the drill was pulled from the plug exposing employees to electrical hazards.   b. Living room: The outer insulation to the power cable for the drill used to stir the adhesive mix was pulled from the drill exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Industrial Gases INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347238248.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.