OSHA Inspection: U.S. DEPARTMENT OF VETERANS AFFAIRS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. DEPARTMENT OF VETERANS AFFAIRS in 202 GOVERNMENT RD, SALISBURY, NC 28144 (NAICS 928110). OSHA activity number 347239105.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Department of Veterans Affairs — free Get an email when a new federal OSHA severe-injury report for U.S. Department of Veterans Affairs is published. One employer, no account, unsubscribe in one click.
Site address
202 GOVERNMENT RD
City
SALISBURY
State
NC
ZIP
28144
Mailing
202 GOVERNMENT RD, SALISBURY, NC 28144
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
50
Ownership type
D

2 citations on file for this inspection.

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 11, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  Employees were exposed to a struck by hazard while working with a bench grinder that lacked a tongue guard on its right side
Recent events (1)
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 11, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(2)(iii):Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.  A bench grinder 110 volt flexible cord had the outer sheath pulled back at the strain relief end connection. Employees were exposed employees to an electrical shock hazard.