EL PASO, TX —
OSHA Inspection: CABINET MASTERS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CABINET MASTERS in 13782 ARANGO DRIVE, EL PASO, TX 79928 (NAICS 337110). OSHA activity number 347239808.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CABINET MASTERS
- Site address
- 13782 ARANGO DRIVE
- City
- EL PASO
- State
- TX
- ZIP
- 79928
- Mailing
- 13782 ARANGO DRIVE, EL PASO, TX 79928
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 20
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.213 C01
- Issued
- Feb 20, 2024
- Penalty
- Initial $7,260 · Current $4,275 Reduced
General-duty citation text
29 CFR 1910.213(c)(1):The hood on each circular hand-fed ripsaw was not made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. Raw Materials Storage: On or about January 26, employees were exposed to amputation and struck-by hazards due to an improperly guarded table saw.
Recent events (2)
- — I (S) $4275
- — Z (S) $7260
1910.305 B02 I
- Issued
- Feb 20, 2024
- Penalty
- Initial $7,260 · Current $4,275 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: Paint Area: On or about January 29, 2024, employees were exposed to electrical shock hazards due to an outlet missing a faceplate and exposed live conductors.
Recent events (2)
- — I (S) $4275
- — Z (S) $7260
1910.134 C01
- Issued
- Feb 20, 2024
- Abate by
- Mar 8, 2024
- Penalty
- Initial $815 · Current $450 Reduced
9211
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: Woodworking Shop: On or about January 29, 2024, employees were exposed to sawdust inhalation hazards due to the lack of a respiratory protection program.
Recent events (2)
- — I (O) $450
- — Z (O) $815
More inspections at Cabinet Masters
View Cabinet Masters's full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347239808.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.