Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: C & C DRYWALL CONTRACTORS NORTH INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of C & C DRYWALL CONTRACTORS NORTH INC in 300 EAST STREET, CAMDEN, DE 19934 (NAICS 238130). OSHA activity number 347240095.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C & C Drywall Contractors North INC for free Get an email when a new federal OSHA severe-injury report for C & C Drywall Contractors North INC is published. One employer, no account, unsubscribe in one click.
Site address
300 EAST STREET
City
CAMDEN
State
DE
ZIP
19934
Mailing
730 HORSEPOND ROAD, DOVER, DE 19901
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
25
Ownership type
Private (A)

5 citations on file for this inspection.

1910.1200 E01 I

Serious Gravity 1 1 instance 8 exposed
Issued
Apr 25, 2024
Penalty
Initial $2,765 · Current $1,936 Reduced
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet.  a) The Reserve on East Apartment Complex Community Building at 300 East Street, Camden-Wyoming, DE 19934: On or about January 29, 2024, a chemical inventory list identifying the hazardous chemicals being used by their employees was not compiled or presented on site.
Recent events (2)
  • · I (S) $1935.5
  • · Z (S) $2765

1910.1200 H01

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 25, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) The Reserve on East Apartment Complex Community Building at 300 East Street, Camden-Wyoming, DE 19934: On or about January 29, 2024, employees were not provided training on hazardous chemicals to be used on the site nor did the employer provide SDS sheets for the employees to reference in case there was an exposure.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 25, 2024
Penalty
Initial $3,687 · Current $2,581 Reduced
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:  a) The Reserve on East Apartment Complex Community Building at 300 East Street, Camden-Wyoming, DE 19934: On or about January 29, 2024, employees building a temporary wall using Pneumatic Framing Nailer/Gun were not wearing any type of eye protection to protect from physical hazards of being struck.
Recent events (2)
  • · I (S) $2580.9
  • · Z (S) $3687

1926.150 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 25, 2024
Penalty
Initial $5,531 · Current $3,872 Reduced
29 CFR 1926.150(a)(1): The employer did not develop a fire protection program for all phases of the construction or demolition work:  a) The Reserve on East Apartment Complex Community Building at 300 East Street, Camden-Wyoming, DE 19934: On or about January 29, 2024, employees worked inside the building without any type of fire protection program explaining exit route points or accountability procedures.
Recent events (2)
  • · I (S) $3871.7
  • · Z (S) $5531

1926.150 C01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 25, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof:  a) The Reserve on East Apartment Complex Community Building at 300 East Street, Camden-Wyoming, DE 19934: On or about January 29, 2024, employees worked at the site without having any type of fire extinguishing equipment in the event of a fire.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347240095.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.