WHEELING, IL —
OSHA Inspection: BALANCED ENVIRONMENTS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BALANCED ENVIRONMENTS, INC. in DUNDEE ROAD AND MILWAUKEE AVE., WHEELING, IL 60090 (NAICS 561730). OSHA activity number 347241010.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BALANCED ENVIRONMENTS, INC.
- Site address
- DUNDEE ROAD AND MILWAUKEE AVE.
- City
- WHEELING
- State
- IL
- ZIP
- 60090
- Mailing
- 17950 W. ILLINOIS ROUTE 173, OLD MILL CREEK, IL 60083
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561730
- Employees
- 15
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.67 C02 V
- Issued
- Mar 7, 2024
- Penalty
- Initial $10,372 · Current $7,500 Reduced
General-duty citation text
29 CFR 1910.67(c)(2)(v): A personal fall arrest or travel restraint system that meets the requirements in 29 CFR part 1910, subpart I, was not worn and attached to the boom or basket when working from an aerial lift: a) On or about January 29, 2024, employees were exposed to the hazard of falling from an elevation of approximately 20 feet while working from a Genie aerial lift without fall protection. a) On or about January 29, 2024, employees were exposed to the hazard of falling from an elevation of approximately 40 feet while working from a Versalift aerial lift without fall protection. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $7500
- — Z (S) $10372
1910.304 B03 II A
- Issued
- Mar 7, 2024
- Penalty
- Initial $10,372 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.304(b)(3)(ii)(A): All 125-volt, single-phase, 15-, 20-, and 30-ampere receptacle outlets that are not part of the permanent wiring of the building or structure and that are in use by personnel were not equipped with ground-fault circuit-interrupter protection for personnel: a) On or about January 29, 2024, employees were provided with electrical equipment connected by cord and plug to a Brute portable generator, having 5250 watts of start-up power, without the use of ground fault circuit interrupters or an assured equipment grounding conductor program. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $5000
- — Z (S) $10372
More inspections at Balanced Environments, INC.