Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JR EXCAVATION, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of JR EXCAVATION, INC. in CONSTRUCTION SITE NORTH NORTHEAST OF 7450 W 52ND AVE. 7494 WADSWORTH BLVD., ARVADA, CO 80002 (NAICS 238910). OSHA activity number 347241382.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JR Excavation, INC. — free Get an email when a new federal OSHA severe-injury report for JR Excavation, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
JR EXCAVATION, INC.
Site address
CONSTRUCTION SITE NORTH NORTHEAST OF 7450 W 52ND AVE. 7494 WADSWORTH BLVD.
City
ARVADA
State
CO
ZIP
80002
Mailing
1207 MIKA PL., CASTLE ROCK, CO 80104
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238910
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.651 A

Serious Gravity 10 4 instances 4 exposed
Issued
Jul 10, 2024
Abate by
Jul 30, 2024
Penalty
Initial $4,839 · Current $4,839
29 CFR 1926.651(a): All surface encumbrances that were located so as to create a hazard to employees were not removed or supported, as necessary, to safeguard employees:  (a) On or about January 27, 2024, the employer did not ensure employees working inside an excavation that measured approximately 6 feet in depth were protected, in that a John Deere  624L Wheel Loader, with an operating weight in excess of 34,000 pounds, was parked adjacent to the southwest access ramp of the excavation. Employees were working at the bottom of the excavation while being outside the protection of a shield system. This condition exposed employees to a crushing hazard by excavation wall cave-in.  (b) On or about January 27, 2024, the employer did not ensure employees working inside an excavation that measured approximately 6 feet in depth were protected, in that a John Deere  200G,-Tier, Mid-Size Excavator, with an operating weight  in excess of 45,000 pounds, was parked on top of the primary spoil pile directly adjacent to and along the West side of the of the excavation. Employees were working at the bottom of the excavation while being outside the protection of a shield system. This condition exposed employees to a crushing hazard by excavation wall cave-in.  (c) On or about January 27, 2024, the employer did not ensure employees working inside an excavation that measured approximately 6 feet in depth were protected, in that the spoil pile for the approximate  34,918 Cubic Feet of earth removed from the excavation, was positioned directly adjacent to the excavation.  Employees were working at the bottom of the excavation while being outside the protection of a shield system. This condition exposed employees to a crushing hazard by excavation wall cave-in.  (d)  On or about January 27, 2024, the employer did not ensure employees working inside an excavation that measured approximately 6 feet in depth were protected, in that the approximately 36 concrete pipes were positioned directly adjacent to the exaction, along the South edge and the earthen access ramp.  Employees were working at the bottom of the excavation while being outside the protection of a shield system. This condition exposed employees to a crushing hazard by excavation wall cave-in.
Recent events (1)
  • — Z (S) $4839

1926.651 J02

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 10, 2024
Abate by
Jul 30, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.651(j)(2):  Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.  (a) On or about January 27, 2024, the employer did not ensure that the spoil pile was at least two feet from the edge of the excavation.  Employees worked in the excavation that was approximately 133 ft long,  43 ft wide, and 6 ft deep.  The approximate  34,918 cubic feet of materials removed from the excavation was staged directly adjacent to the West excavation wall and ran the 133 ft length of the excavation.   This condition exposed the employees to the hazard of spoil pile material falling into the excavation or causing the excavation wall to collapse.
Recent events (1)
  • — Z (S) $0

1926.651 K01

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 10, 2024
Abate by
Jul 30, 2024
Penalty
Initial $4,839 · Current $4,839
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions:  (a) On or about January 27, 2024, the employer did not ensure that a daily inspection of the excavation was conducted prior to employees working inside the trench, in that employees who were installing a water detention systems inside an excavation were protected by an adequate protective system.  The excavation had near vertical walls, which were approximately six feet deep.  This condition exposed subcontractor employees to a crushing hazard by excavation wall cave-in.
Recent events (1)
  • — Z (S) $4839

1926.652 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 10, 2024
Abate by
Jul 30, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions:  (a) On or about January 27, 2024, the employer did not ensure that a daily inspection of the excavation was conducted prior to employees working inside the excavation, in that employees who were installing a water detention systems inside an excavation were protected by an adequate protective system.  The excavation had near vertical walls, which were approximately six feet deep.  This condition exposed subcontractor employees to a crushing hazard by excavation wall cave-in.
Recent events (1)
  • — Z (S) $0

1926.651 C02

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 10, 2024
Abate by
Jul 30, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  (a) On or about January 27, 2024, the employer did not ensure that a stairway, ladder, ramp or other safe means of egress was provided to employees that worked in an excavation that was approximately 6 feet in depth, 43 feet in width, and 133 feet in length, with a single earthen ramp located at the excavations Southwest corner.  This condition did not provide employees with a safe means of egress.
Recent events (1)
  • — Z (S) $0