Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DAYTON ROOFING AND RESTORATION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DAYTON ROOFING AND RESTORATION LLC in 137 E. CENTER ST., MARION, OH 43302 (NAICS 238160). OSHA activity number 347245623.

Watch Dayton Roofing AND Restoration LLC — free Get an email when a new federal OSHA severe-injury report for Dayton Roofing AND Restoration LLC is published. One employer, no account, unsubscribe in one click.
Site address
137 E. CENTER ST.
City
MARION
State
OH
ZIP
43302
Mailing
55 APPLEBLOSSOM PL., BEAVERCREEK, OH 45440
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4839.00 · Current $4839.00
29 CFR  1926.501(b)(10):Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems:  On or about January 31, 2024 the employer Dayton Roofing and Restoration LLC at jobsite located at 137 E. Center St. Marion OH 43302, did not ensure employees were protected from falls while performing roofing activities atop a low sloped commercial structure. Two employees cleaning and making flat roof repairs on the commercial structure were exposed to a falls of 12 feet and 3 inches or greater to the ground below. The roof was a 2:12 pitch.
Recent events (1)
  • — Z (S) $4839

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4839.00 · Current $4839.00
29 CFR  1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  On or about January 31, 2024 the employer Dayton Roofing and Restoration LLC at jobsite located at 137 E. Center St. Marion OH 43302, did not ensure the side rails of one portable Little Giant Multi-purpose ladder (S/N 21012S) was extended at least three feet above the landing surface. Two employees were exposed to falls from approximately 12 feet or greater from the top of the second (roof) level to the decking below while using the ladder to access the second (roof) level to perform commercial roofing repair activities on a commercial building.
Recent events (1)
  • — Z (S) $4839

1926.503 B01

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.503(b)(1):The employer did not verify fall protection training by preparing a written certification record.  On or about January 31, 2024 the employer Dayton Roofing and Restoration LLC at jobsite located at 137 E. Center St. Marion OH 43302, did not develop or maintain a written record of certification for all employees who might be exposed to fall hazards.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347245623.