APOLLO BEACH, FL ·
OSHA Inspection: CAPSULE CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CAPSULE CONSTRUCTION LLC in 6192 HIDDEN BRANCH DRIVE, APOLLO BEACH, FL 33572 (NAICS 238160). OSHA activity number 347259350.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CAPSULE CONSTRUCTION LLC
- Site address
- 6192 HIDDEN BRANCH DRIVE
- City
- APOLLO BEACH
- State
- FL
- ZIP
- 33572
- Mailing
- 11125 SAILBROOKE DRIVE, RIVERVIEW, FL 33579
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.102 A01
- Issued
- Feb 15, 2024
- Penalty
- Initial $3,457 · Current $2,420 Reduced
General-duty citation text
29 CFR 1926.102(a)(1):Employees did not use eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: On the roof at a residence, located at 6192 Hidden Branch Drive, Apollo Beach, Florida 33579: On or about 2/6/24, the employer exposed employees to struck by hazards, in that safety glasses were not utilized by employees operating air powered nail guns while performing roofing work.
Recent events (2)
- · I (S) $2419.9
- · Z (S) $3457
1926.501 B13
- Issued
- Feb 15, 2024
- Penalty
- Initial $4,839 · Current $3,387 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On the roof at a residence, located at 6192 Hidden Branch Drive, Apollo Beach, Florida 33579: On or about 2/6/24, the employer exposed employees to fall hazards, in that fall protection was not utilized by employees while performing framing activities at an approximate exposure height of 19 feet.
Recent events (2)
- · I (S) $3387.3
- · Z (S) $4839
More inspections in this industry (NAICS 238160)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347259350.