Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: T&B BOILER, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of T&B BOILER, INC. in 816 VINSON LANE, RED OAK, TX 75154 (NAICS 332913). OSHA activity number 347264624.

Watch T&B Boiler, INC. — free Get an email when a new federal OSHA severe-injury report for T&B Boiler, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
T&B BOILER, INC.
Site address
816 VINSON LANE
City
RED OAK
State
TX
ZIP
75154
Mailing
816 VINSON LANE, RED OAK, TX 75154
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332913
Employees
17
Ownership type
A

4 citations on file for this inspection.

1910.215 A04

Serious Gravity 1 1 instance 6 exposed
Issued
Penalty
Initial $2350.00 · Current $1410.00 Reduced
29 CFR  1910.215(a)(4):Grinding machinery was not used with work rest(s) to support offhand grinding work.  On or about February 6, 2024, and at times prior thereto, in the east bay area, the employer did not ensure a work rest was installed on the 6 inch master mechanic bench grinder exposing them to struck-by hazards.
Recent events (2)
  • — I (S) $1410
  • — Z (S) $2350

1910.215 B09

Serious Gravity 1 1 instance 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel.  On or about February 6, 2024, and at times prior thereto, in the east bay area, the employer did not ensure adjustable tongue guards were installed prior to employees operating the table grinder, exposing them to struck-by flying objects.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B02 IV

Other-than-serious 1 instance 6 exposed
Issued
Penalty
Initial $440.00 · Current $264.00 Reduced
29 CFR  1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use.  On or about February 6, 2024, and at times prior thereto, unused compressed air cylinders were stored without the protective cap exposing employees to struck-by hazards.  a)  South bay area, one oxygen compressed cylinder was stored without the safety cap, b)  South bay area, one Acetylene cylinder was stored without the safety cap.
Recent events (2)
  • — I (O) $264
  • — Z (O) $440

1910.305 G02 III

Other-than-serious 1 instance 6 exposed
Issued
Penalty
Initial $440.00 · Current $264.00 Reduced
29 CFR  1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screw.  On or about February 6, 2024, and at times prior thereto, in the west bay area, the employer's Eaton General Duty switch box power cord had the outer sheathing pulled away from the terminal exposing the internal wiring exposing employees to electrical shock hazards.
Recent events (2)
  • — I (O) $264
  • — Z (O) $440

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347264624.