WASHINGTON, DC —
OSHA Inspection: PROTECTOR MANAGEMENT CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PROTECTOR MANAGEMENT CORP. in 4625 VAN NESS STREET NW, WASHINGTON, DC 20016 (NAICS 236116). OSHA activity number 347269086.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROTECTOR MANAGEMENT CORP.
- Site address
- 4625 VAN NESS STREET NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20016
- Mailing
- 8855 ANNAPOLIS RD. STE. 205, LANHAM, MD 20706
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 15
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Aug 5, 2024
- Abate by
- Aug 13, 2024
- Penalty
- Initial $6,033 · Current $6,033
General-duty citation text
29 CFR 1926.102(a)(1):Employees did not use eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) On or about February 8, 2024, at a worksite located at 4625 Van Ness Street NW, second floor; employees engaged in framing were not wearing eye protection provided while operating pneumatic tools such as nail guns. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $6033
1926.403 B02
- Issued
- Aug 5, 2024
- Abate by
- Aug 13, 2024
- Penalty
- Initial $3,448 · Current $3,448
General-duty citation text
29 CFR 1926.403(b)(2):Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) On or about February 8, 2024, at a worksite located at 4625 Van Ness Street NW, second floor, employees engaged in residential construction activities were using an electrical non-metallic wall box designed to be mounted as an outlet extension cord exposing the employees to a shock hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $3448
1926.404 B01 II
- Issued
- Aug 5, 2024
- Abate by
- Aug 13, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(ii):On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection. a) On or about February 8, 2024, at a worksite located at 4625 Van Ness Street NW, first-floor area, employees were exposed to electrical shock while operating portable electrical equipment such as circular saws that were not connected to a ground-fault circuit interrupter while framing the residential home. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $0
1926.405 B02
- Issued
- Aug 5, 2024
- Abate by
- Aug 13, 2024
- Penalty
- Initial $3,448 · Current $3,448
General-duty citation text
29 CFR 1926.405(b)(2):In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: a) On or about February 8, 2024, at a worksite located at 4625 Van Ness Street NW, first-floor area, employees were exposed to electrical shock while plugging portable electrical equipment such as compressors and saws into outlets with missing faceplates. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $3448
1926.501 B13
- Issued
- Aug 5, 2024
- Abate by
- Aug 13, 2024
- Penalty
- Initial $12,066 · Current $12,066
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about February 8, 2024, at a worksite located at 4625 Van Ness Street NW, second floor, employees were observed walking the top plate while installing the trusses on the residential home without fall protection in place to protect them, falling approximately 20 feet to ground level. b) On or about February 8, 2024, at a worksite located at 4625 Van Ness Street NW, first-floor area, the stairs used to access the upper floor were not protected with railing, exposing the employees to a 10-foot fall to the wooden deck below. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records. The Protector Construction was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1443591, citation number 1, item number 1 and was affirmed as a final order on (9/8/2020, with respect to a workplace located at 246 11th Street NE Washington DC 20010.
Recent events (1)
- — Z (R) $12066
More inspections at Protector Management Corp.
View Protector Management Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 236116)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347269086.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.