Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: C&H CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C&H CONSTRUCTION in 210 S. MAIN ST, WEST MANCHESTER, OH 45382 (NAICS 238160). OSHA activity number 347273146.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C&H Construction — free Get an email when a new federal OSHA severe-injury report for C&H Construction is published. One employer, no account, unsubscribe in one click.
Establishment
C&H CONSTRUCTION
Site address
210 S. MAIN ST
City
WEST MANCHESTER
State
OH
ZIP
45382
Mailing
6090 JENNAGATE DR, DAYTON, OH 45424
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

3 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 8 exposed
Issued
May 13, 2024
Abate by
May 31, 2024
Penalty
Initial $4,839 · Current $4,839
29 CFR  1926.20(b)(2):Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employer  a) On February 8, 2024, the employer did not ensure that a frequent and regular inspection program of the job site and equipment was being performed by a competent person, and as a result, no fall protection systems and/or devices were installed and utilized exposing employees to fall hazards; employees were also exposed to fall hazards while using ladders positioned at angles greater than a 4:1 ratio. Fall height measured to be 11'3" from the ground to the roof's eave.
Recent events (1)
  • — Z (S) $4839

1926.501 B13

Serious Gravity 10 1 instance 8 exposed
Issued
May 13, 2024
Abate by
May 31, 2024
Penalty
Initial $4,839 · Current $4,839
29 CFR  1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  a.) On February 8, 2024, the employer failed to ensure employees were protected from falls as they conducted roofing work on a 16-12 pitched roof in that no fall protection system was set or provided for employees exposing them to a fall hazard of 11'3".
Recent events (1)
  • — Z (S) $4839

1926.1053 B05 I

Serious Gravity 10 1 instance 8 exposed
Issued
May 13, 2024
Abate by
May 31, 2024
Penalty
Initial $4,839 · Current $4,839
29 CFR  1926.1053(b)(5)(i): Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).    a) On February 8, 2024, the employer did not ensure that ladders being used by employees for residential roofing work were set up at an angel equal to one-quarter of the working length (0.25); in that, the ladders were being used at a set up ratio of 0.6, exceeding the required ratio of non-self-supporting ladders by more than twice (2.4) and exposing employees to fall hazard of 11 feet 3 inches to hard ground below.
Recent events (1)
  • — Z (S) $4839

View C&H Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347273146.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.